Advancements in Targeted Ultramicrotomy for Correlative and Volume Electron Microscopy Workflows
Microscopy and Microanalysis · 27.07.2026 · 32 (Supplement_1)
DOI: 10.1093/mam/ozag053.387 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 27.07.2026. Verfasst von Mercedeh Yeganeh. Die Arbeit nennt 2 Literaturangaben.
Abstract (Originalsprache)
Ultramicrotomy is a fundamental step in preparing biological and polymeric materials for transmission electron microscopy (TEM) and volume electron microscopy (volume EM). Challenges such as accurately reaching deep regions of interest, reducing sectioning artifacts, and achieving reproducible ultrathin ribbons continue to impact data quality and workflow efficiency. This paper reviews recent technological advancements in targeted ultramicrotomy and discusses technologies designed to support section quality, targeting precision, and workflow consistency across users. Key developments support micro-computed tomography (micro-CT)-guided trimming, fluorescence-guided plane alignment, and stabilized serial sectioning for three-dimensional (3D) reconstruction workflows. Micro-CT-guided trimming utilizes non-destructive 3D X-ray imaging prior to sectioning to map the spatial distribution of structures within a resin block. Depth and orientation information extracted from micro-CT datasets can be linked to trimming parameters, guiding selective and automated removal of resin. This approach helps ensure that relevant regions reach the block surface efficiently and with appropriate geometry, reducing unnecessary trimming, preserving sample volume, and improving sectioning approach angles. The result is a block face that is more predictable and aligned with the intended cutting plane (Fig. 1). Fluorescence-guided sectioning integrates real-time optical imaging into the trimming and cutting workflow. Fluorescent markers remain visible within the embedded sample, allowing users to observe the precise location of labeled cells, organelles, or structures of interest as trimming progresses. This capability supports informed adjustments to block orientation and ensures that ultrathin sections intersect the target structure at the desired depth and angle. The approach reduces user-dependent variability and improves the likelihood of capturing relevant biological features in the earliest collected sections (Fig. 2). Advancements in serial sectioning incorporate mechanical and environmental stabilization strategies designed specifically for volume EM workflows. These include vibration-damping cutting mechanics, active thermal control to minimize knife drift, and automated software tools that maintain ribbon alignment and support section-by-section tracking. Together, these features enable the generation of longer and more uniform section ribbons while reducing section compression, folds, and section loss that can interrupt 3D reconstructions. Collectively, these innovations expand the capabilities of ultramicrotomy in correlative light and electron microscopy (CLEM) and volume EM workflows, providing greater consistency in accessing subcellular features and improving overall workflow reliability [1,2]. Illustration of a micro-CT-guided trimming workflow. Resin block with embedded Platynereis D. larvae shown in the UC Enuity target trimming interface before (upper row) and after (lower row) trimming based on three-dimensional micro-CT data. The upper panels show the green target plane selected by the user, indicating how the sample block will be trimmed. Images and samples courtesy of Viola Oorschot and Ines Romero-Brey (EMCF and the Schwab Team, Cell Biology and Biophysics Unit, EMBL Heidelberg, Germany). Results of fluorescence-guided automatic trimming. Mammalian cells cultured on sapphires and embedded in HM20 to preserve in-resin fluorescence. Upper left: overview of the sample in Mesacut view (scale bar = 100 µm). Upper right: magnified image of the resulting block face with cells indicated by arrows (scale bar = 100 µm). Lower left: 100 nm thin sections in the knife boat (scale bar = 500 µm). Lower right: target cells visualized in the section (scale bar = 100 µm). Sample courtesy of Felix Gaedke, PhD, CECAD, Cologne, Germany.
Zitieren
APA
Yeganeh, M. (2026). Advancements in Targeted Ultramicrotomy for Correlative and Volume Electron Microscopy Workflows. Microscopy and Microanalysis, 32(Supplement_1). https://doi.org/10.1093/mam/ozag053.387
Vancouver
Yeganeh M. Advancements in Targeted Ultramicrotomy for Correlative and Volume Electron Microscopy Workflows. Microscopy and Microanalysis. 2026;32(Supplement_1). doi:10.1093/mam/ozag053.387
BibTeX
@article{Yeganeh2026,
author = {Yeganeh, Mercedeh},
title = {Advancements in Targeted Ultramicrotomy for Correlative and Volume Electron Microscopy Workflows},
journal = {Microscopy and Microanalysis},
year = {2026},
volume = {32},
number = {Supplement_1},
doi = {10.1093/mam/ozag053.387}
}
EUVIMED