Feedback Controlled PWM of the Electron Beam for Damage Reduction

Christopher T Nelson, Ondrej Dyck, Andrew Lupini, Kai Xiao, Stephen Jesse

Microscopy and Microanalysis · 27.07.2026 · 32 (Supplement_1)

DOI: 10.1093/mam/ozag053.352 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 27.07.2026. Verfasst von Christopher T Nelson und 4 weiteren Autor:innen. Die Arbeit nennt 4 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The STEM is an extremely powerful tool for high spatial resolution characterization. Through controlled use of the beam-sample interactions it can also be a powerful tool for high resolution synthesis, as the success of electron lithography can attest. One such application is the directed formation of quantum point defects in 2D materials. This is not limited to subtractive defects, e.g. creating vacancies. It can also be additive where a dopant source is used to fill a generated vacancy [1]. But such synthesis cannot be done blind, the STEM requires setup, alignment, and up to atomic-precision targeting. Moreover, live STEM imaging is usually used in tandem to track the synthesis process, for instance to detect the dopant filling of the vacancy. So the beam must simultaneously serve a dual purpose, a transformative tool for synthesis, and a passive probe otherwise. Since these processes require transformative beam-sample interactions, they preclude using beam settings to mitigate damage such as voltages below knock-on thresholds or low currents. In this work we explore a method of rapid beam current adjustment to help mitigate damage in an above knock-on regime. Recent work has demonstrated the rapid shuttering of an electrostatic blanker combined with signal feedback event detection can optimize signal-to-noise while minimizing dose [2]. Here we present a similar strategy based on feedback-driven Pulsed Width Modulation (PWM) of the beam. Our dose-control strategy is to dynamically scale the beam current using a PWM electron source via an electrostatic blanker, allowing fine-tuned control of the current without disturbing the other electron-optic elements in the column. This consists of rapidly cycling the beam on and off while the ratio of on and off time is adjusted. The PWM duty cycle is determined by a PID feedback loop of the HAADF detector signal. The feedback and scan controls are controlled by an FPGA, with the blanker signal driving a custom voltage amplifier stage to the blanker plates. For the 50kHz PWM frequency used here we have an available PWM duty cycle range of 0.7% to 99.3%. To demonstrate the feedback-PWM we image a WS2 monolayer, a promising host for quantum defects such as Co substitutional defects for S [3]. As a semiconductor it is sensitive to both radiolysis and, at the 100kV we use here, knock-on damage. Figure 1 compares the results of the feedback-PWM scanning to a standard HAADF scan. There are two signal channels, the HAADF and the duty cycle, which each illustrate a damage reduction mode. The PWM reduces the effective beam current which lowers the HAADF signal toward the feedback setpoint. Meanwhile the duty cycle image shows how the dose is apportioned away from the atomic nuclei to reduce knock-on damage. To quantify the beam damage the WS2 monolayer was subjected to small area continuous time-series and the hole formation was tracked. A plot of the hole area versus dose in Figure 2 depicts a roughly two-fold increase in the dose for hole onset and growth rates [4]. Feedback PWM Imaging. HAADF-STEM imaging of monolayer WS2 using (a) standard imaging, without any PWM or feedback, (b) feedback controlled PWM. The left two columns are the raw HAADF and duty cycle signals. The right two columns are the reconstructed equivalent full-dose HAADF image and corresponding FFT. The images are 37x27Å scanned at 128x128 pixels. The data shown are sums of the respective time series to 1.5·106 e-/A^2 cumulative dose. Hole Formation Comparison. (A) Summary plot of the hole area vs. cumulative dose for standard HAADF (red) and feedback PWM (blue). The statistic plotted is the dose required for given hole size. The solid curves are the mean values and color bands span the 1st and 3rd quartiles. The same plots for individual runs are given for the (B) Feedback PWM, and (C) Standard datasets.

Zitieren

APA

Nelson, C. T., Dyck, O., Lupini, A., Xiao, K., & Jesse, S. (2026). Feedback Controlled PWM of the Electron Beam for Damage Reduction. Microscopy and Microanalysis, 32(Supplement_1). https://doi.org/10.1093/mam/ozag053.352

Vancouver

Nelson CT, Dyck O, Lupini A, Xiao K, Jesse S. Feedback Controlled PWM of the Electron Beam for Damage Reduction. Microscopy and Microanalysis. 2026;32(Supplement_1). doi:10.1093/mam/ozag053.352

BibTeX
@article{Nelson2026,
  author = {Nelson, Christopher T and Dyck, Ondrej and Lupini, Andrew and Xiao, Kai and Jesse, Stephen},
  title = {Feedback Controlled PWM of the Electron Beam for Damage Reduction},
  journal = {Microscopy and Microanalysis},
  year = {2026},
  volume = {32},
  number = {Supplement_1},
  doi = {10.1093/mam/ozag053.352}
}
Kostenlos starten →