Liquid Helium TEM Sample Holder: Swift Cool-Down and Long Holding Time
Microscopy and Microanalysis · 27.07.2026 · 32 (Supplement_1)
DOI: 10.1093/mam/ozag053.106 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 27.07.2026. Verfasst von Denys Sutter und 5 weiteren Autor:innen. Die Arbeit nennt 6 Literaturangaben.
Abstract (Originalsprache)
Quantum materials host unique electronic and magnetic properties—including superconductivity, charge and spin ordering—predominantly observed at cryogenic temperatures [1,2]. While progress in cryogenic transmission electron microscopy (TEM) methodologies have led to the development of liquid nitrogen (LN2) cooled side-entry sample holders and cartridge-integrated microscopes tailored to suit the demands of life sciences, the exploration of such phase transitions within quantum materials typically necessitates adjustable temperatures with a base in the liquid helium (LHe) range [3]. LHe solutions for high-resolution imaging in electron microscopes have been developed with base temperatures as low as 1.5 K maintainable over a continuous five-hour timespan [4]. Unfortunately, such solutions, constructed in a cryo-stage setup, which combine superfluid helium alongside LN2-cooled shields, cannot be easily adapted to the tight spatial constraints of the much more technically versatile side-entry holders. Until recently, commercially available LHe side-entry holders have been limited by considerable mechanical and thermal instability, as well as short base-temperature holding times due to the limited cryogen storage capacity of the dewar attached to the holder. We present recent innovations of a lightweight, ultra-low-temperature LHe TEM sample holder, with eight electrical contacts for biasing capabilities. From room temperature, a base temperature of 5.2 K (as measured adjacent to the sample) can be attained within one minute and sustained with a stability of +/- 2.5 mK for days. Here, we demonstrate our recent achievements in the latest LHe cryo-TEM setup and upcoming developments with MEMS devices for heating and biasing [5,6]. Left: Cool-down curve of the condenZero liquid helium sample holder. Right: Selected area diffraction pattern of NbSe2 at low temperatures showing charge density wave Bragg peaks. Data taken from [5] Left: Close-up view of sample holder with wire bonds structure for electrical biasing measurement in the inset. Right: Superconducting transition temperature of NbN measured in a vacuum chamber, compared against calibrated data from a physical property measurement system. Data taken from [6].
Zitieren
APA
Sutter, D., Thomsen, J. D., Lu, P., Hosseinkhannazer, H., Biscette, D., & Dunin-Borkowski, R. E. (2026). Liquid Helium TEM Sample Holder: Swift Cool-Down and Long Holding Time. Microscopy and Microanalysis, 32(Supplement_1). https://doi.org/10.1093/mam/ozag053.106
Vancouver
Sutter D, Thomsen JD, Lu P, Hosseinkhannazer H, Biscette D, Dunin-Borkowski RE. Liquid Helium TEM Sample Holder: Swift Cool-Down and Long Holding Time. Microscopy and Microanalysis. 2026;32(Supplement_1). doi:10.1093/mam/ozag053.106
BibTeX
@article{Sutter2026,
author = {Sutter, Denys and Thomsen, Joachim Dahl and Lu, Peng-Han and Hosseinkhannazer, Hooman and Biscette, Dominik and Dunin-Borkowski, Rafal E},
title = {Liquid Helium TEM Sample Holder: Swift Cool-Down and Long Holding Time},
journal = {Microscopy and Microanalysis},
year = {2026},
volume = {32},
number = {Supplement_1},
doi = {10.1093/mam/ozag053.106}
}
EUVIMED