Intravital Microscopy With an Airy Beam Light Sheet Microscope Improves Temporal Resolution and Reduces Surgical Trauma

Rebekka I Stegmeyer iD, Malte Stasch iD, Daniel Olesker iD, Jonathan M Taylor iD, Thomas J Mitchell iD, Neveen A Hosny iD, Nils Kirschnick iD, Gunnar Spickermann iD, Dietmar Vestweber iD, Stefan Volkery iD

Microscopy and Microanalysis · 2024

DOI: 10.1093/mam/ozae099 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy and Microanalysis, 2024. Verfasst von Rebekka I Stegmeyer und 9 weiteren Autor:innen. Beteiligte Einrichtung: Max Planck Institute for Molecular Biomedicine, Department Vascular Cell Biology, Röntgenstraße 20, 48161 Münster, North Rhine-Westphalia, Germany. Hauptthemen laut MEDLINE: Intravital Microscopy. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Scientist Programme InFlame, Else Kröner-Fresenius Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intravital microscopy has emerged as a powerful imaging tool, which allows the visualization and precise understanding of rapid physiological processes at sites of inflammation in vivo, such as vascular permeability and leukocyte migration. Leukocyte interactions with the vascular endothelium can be characterized in the living organism in the murine cremaster muscle. Here, we present a microscopy technique using an Airy Beam Light Sheet microscope that has significant advantages over our previously used confocal microscopy systems. In comparison, the light sheet microscope offers near isotropic optical resolution and faster acquisition speed, while imaging a larger field of view. With less invasive surgery we can significantly reduce side effects such as bleeding, muscle twitching, and surgical inflammation. However, the increased acquisition speed requires exceptional tissue stability to avoid imaging artefacts. Since respiratory motion is transmitted to the tissue under investigation, we have developed a relocation algorithm that removes motion artefacts from our intravital microscopy images. Using these techniques, we are now able to obtain more detailed 3D time-lapse images of the cremaster vascular microcirculation, which allow us to observe the process of leukocyte emigration into the surrounding tissue with increased temporal resolution in comparison to our previous confocal approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intravital MicroscopyAnimalsMiceLeukocytesMicroscopy, Confocal

Stichwörter der Autor:innen

airy beaminflammationintravital microscopylight sheet microscopynon-invasive imaging

Autor:innen und Institutionen

  • Max Planck Institute for Molecular Biomedicine, Department Vascular Cell Biology, Röntgenstraße 20, 48161 Münster, North Rhine-Westphalia, Germany.
  • Max Planck Institute for Molecular Biomedicine, BioOptic Service Unit, Röntgenstraße 20, 48161 Münster, North Rhine-Westphalia, Germany.
  • School of Physics and Astronomy, University of Glasgow, University Avenue B8 Kelvin Building, G12 8QQ, Glasgow, UK.
  • M Squared Life Limited, 14 East Bay Lane, The Press Centre, Here East, Queen Elizabeth Park, Stratford, E15 2GW, London, UK.

ORCID-Profile: Rebekka I Stegmeyer, Malte Stasch, Daniel Olesker, Jonathan M Taylor, Thomas J Mitchell, Neveen A Hosny, Nils Kirschnick, Gunnar Spickermann, Dietmar Vestweber, Stefan Volkery

Förderung

  • Medical Scientist Programme InFlame
  • Else Kröner-Fresenius Foundation

Zitieren

APA

Stegmeyer, R. I., Stasch, M., Olesker, D., Taylor, J. M., Mitchell, T. J., Hosny, N. A., Kirschnick, N., Spickermann, G., Vestweber, D., & Volkery, S. (2024). Intravital Microscopy With an Airy Beam Light Sheet Microscope Improves Temporal Resolution and Reduces Surgical Trauma. Microscopy and Microanalysis. https://doi.org/10.1093/mam/ozae099

Vancouver

Stegmeyer RI, Stasch M, Olesker D, Taylor JM, Mitchell TJ, Hosny NA, et al. Intravital Microscopy With an Airy Beam Light Sheet Microscope Improves Temporal Resolution and Reduces Surgical Trauma. Microscopy and Microanalysis. 2024. doi:10.1093/mam/ozae099

BibTeX
@article{Stegmeyer2024,
  author = {Stegmeyer, Rebekka I and Stasch, Malte and Olesker, Daniel and Taylor, Jonathan M and Mitchell, Thomas J and Hosny, Neveen A and Kirschnick, Nils and Spickermann, Gunnar and Vestweber, Dietmar and Volkery, Stefan},
  title = {Intravital Microscopy With an Airy Beam Light Sheet Microscope Improves Temporal Resolution and Reduces Surgical Trauma},
  journal = {Microscopy and Microanalysis},
  year = {2024},
  doi = {10.1093/mam/ozae099}
}
Kostenlos starten →