EUVIMEDEUVIMED entdecken
Validierungsstudie

Measles ( rubeola) virus qualitative real-time reverse transcription–polymerase chain reaction assay: development and clinical validation on an automated workflow

Lan Yu, Li Chen, Kevin Dumas, Nickolas Weyandt, Michael Meyers, Pei Irwin, Jennifer L Eitson, John W Schoggins, Jason Y Park iD

Laboratory Medicine · 05.10.2026 · 57 (6)

DOI: 10.1093/labmed/lmag075 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Laboratory Medicine, online erschienen am 09.10.2026. Verfasst von Lan Yu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, University of Texas Southwestern Medical Center, Dallas, TX, United States. Hauptthemen laut MEDLINE: Measles virus, Measles, Real-Time Polymerase Chain Reaction, Reverse Transcriptase Polymerase Chain Reaction. Die Arbeit nennt 16 Literaturangaben. Gefördert von: Professorship in Biomedical Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Detection of Measles virus (MeV) RNA is an important method for confirming infection. This study described the clinical validation of a qualitative real-time reverse transcriptase–polymerase chain reaction (RT-PCR) assay for MeV detection.

Methods

A real-time RT-PCR assay was developed and validated using primers and probes previously reported in the literature. The assay was evaluated using reference materials, cultured virus, and previously tested clinical throat swab samples. An automated workflow was established for RNA extraction, RT-PCR amplification, and result reporting using robotic platforms and a real-time PCR instrument. The assay targets the measles nucleoprotein (N) and hemagglutinin (H) genes, with human RNase P gene used as an internal control.

Results

The MeV RT-PCR assay has a limit of detection of 500 genome copies per milliliter. The assay was tested against 85 different samples: 50 positive clinical samples and reference materials and 35 negative clinical samples or reference materials. All expected results were correctly identified, giving 100% sensitivity (50/50) and specificity (35/35). The assay showed 100% interassay and intra-assay reproducibility. No cross-reactivity was observed with other respiratory viruses or common bacterial and fungal pathogens.

Discussion

This automated measles RT-PCR assay demonstrated high accuracy, sensitivity, specificity, and reproducibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Measles virusMeaslesReal-Time Polymerase Chain ReactionReverse Transcriptase Polymerase Chain ReactionHumansSensitivity and SpecificityReproducibility of ResultsWorkflowRNA, ViralAutomation, Laboratory

Stichwörter der Autor:innen

Measles virusRT-PCRautomated workflowautomationclinical validationmeaslestest validation

Substanzen

RNA, Viral

Autor:innen und Institutionen

  • Department of Pathology, University of Texas Southwestern Medical Center, Dallas, TX, United States.
  • Department of Microbiology, University of Texas Southwestern Medical Center, Dallas, TX, United States.
  • Eugene McDermott Center for Human Growth and Development, University of Texas Southwestern Medical Center, Dallas, TX, United States.

ORCID-Profile: Jason Y Park

Förderung

  • Professorship in Biomedical Science

Zitieren

APA

Yu, L., Chen, L., Dumas, K., Weyandt, N., Meyers, M., Irwin, P., Eitson, J. L., Schoggins, J. W., & Park, J. Y. (2026). Measles ( rubeola) virus qualitative real-time reverse transcription–polymerase chain reaction assay: development and clinical validation on an automated workflow. Laboratory Medicine, 57(6). https://doi.org/10.1093/labmed/lmag075

Vancouver

Yu L, Chen L, Dumas K, Weyandt N, Meyers M, Irwin P, et al. Measles ( rubeola) virus qualitative real-time reverse transcription–polymerase chain reaction assay: development and clinical validation on an automated workflow. Laboratory Medicine. 2026;57(6). doi:10.1093/labmed/lmag075

BibTeX
@article{Yu2026,
  author = {Yu, Lan and Chen, Li and Dumas, Kevin and Weyandt, Nickolas and Meyers, Michael and Irwin, Pei and Eitson, Jennifer L and Schoggins, John W and Park, Jason Y},
  title = {Measles ( rubeola) virus qualitative real-time reverse transcription–polymerase chain reaction assay: development and clinical validation on an automated workflow},
  journal = {Laboratory Medicine},
  year = {2026},
  volume = {57},
  number = {6},
  doi = {10.1093/labmed/lmag075}
}
Kostenlos starten →