EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Change management and continuous assurance of laboratory information system–based autoverification rules aligned with ISO 15189:2022: a practical framework for clinical laboratories

Zilin Li, Lujuan Cui, Yinzhi Feng, Shiqian Feng

Laboratory Medicine · 2026

DOI: 10.1093/labmed/lmag060 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Laboratory Medicine, 2026. Verfasst von Zilin Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Xichong County People's Hospital, Nanchong, Sichuan, China. Hauptthemen laut MEDLINE: Clinical Laboratory Information Systems, Laboratories, Clinical. Die Arbeit nennt 20 Literaturangaben. Gefördert von: Nanchong Applied Technology Research and Development Special Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Laboratory information system (LIS)–based autoverification can improve turnaround time, consistency, and workload management, but rules may drift as analytical methods, reagent and calibrator lots, reference ranges, patient case mix, interfaces, and information systems change. This review proposes a standards-anchored framework for governing rules after rule implementation and maintaining patient safety across the rule life cycle.

Methods

Requirements from International Organization for Standardization (ISO) 15189:2022, ISO 22367:2026, Clinical and Laboratory Standards Institute (CLSI) AUTO15, archived CLSI AUTO10-A, and China Health Organization standard WS/T 616-2018 were integrated with select literature on autoverification and patient safety. No patient-identifiable data or new experimental data were used.

Results

The framework consisted of a life cycle model; a taxonomy of change triggers; a 6-domain low, moderate, and high risk assessment; proportionate verification or revalidation methods; a minimum version control and deployment record; monitoring indicators; and discipline-specific considerations for chemistry, immunoassay, hematology, and coagulation. It also defined reference-adjudicated false-pass and false-hold measures and presented a wholly synthetic potassium example.

Discussion

Laboratory information system–based autoverification rules should be managed as controlled, versioned, risk-sensitive clinical decision-support tools through structured change control, risk-proportionate verification or revalidation, and continuous monitoring throughout their life cycle.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Clinical Laboratory Information SystemsLaboratories, ClinicalHumans

Stichwörter der Autor:innen

ISO 15189:2022autoverificationchange managementlaboratory information systempatient safetyquality management

Autor:innen und Institutionen

  • Department of Laboratory Medicine, Xichong County People's Hospital, Nanchong, Sichuan, China.

Förderung

  • Nanchong Applied Technology Research and Development Special Project

Zitieren

APA

Li, Z., Cui, L., Feng, Y., & Feng, S. (2026). Change management and continuous assurance of laboratory information system–based autoverification rules aligned with ISO 15189:2022: a practical framework for clinical laboratories. Laboratory Medicine. https://doi.org/10.1093/labmed/lmag060

Vancouver

Li Z, Cui L, Feng Y, Feng S. Change management and continuous assurance of laboratory information system–based autoverification rules aligned with ISO 15189:2022: a practical framework for clinical laboratories. Laboratory Medicine. 2026. doi:10.1093/labmed/lmag060

BibTeX
@article{Li2026,
  author = {Li, Zilin and Cui, Lujuan and Feng, Yinzhi and Feng, Shiqian},
  title = {Change management and continuous assurance of laboratory information system–based autoverification rules aligned with ISO 15189:2022: a practical framework for clinical laboratories},
  journal = {Laboratory Medicine},
  year = {2026},
  doi = {10.1093/labmed/lmag060}
}