EUVIMEDEUVIMED entdecken
Crossref

Operationalizing accreditation standards for laboratory-developed next-generation sequencing validation of CFTR amplicon-based assays

Muhammad Fareeduddin, Muhammad Usama, Shakir Hussain, Rukhsana Syed Aamir Zahir, Nada Sikander, Javeria Aijaz iD

Laboratory Medicine · 04.08.2026 · 57 (5)

DOI: 10.1093/labmed/lmag049 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laboratory Medicine, online erschienen am 20.08.2026. Verfasst von Muhammad Fareeduddin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Indus Hospital & Health Network, Karachi, Pakistan. Hauptthemen laut MEDLINE: High-Throughput Nucleotide Sequencing, Accreditation, Cystic Fibrosis Transmembrane Conductance Regulator, Laboratory Proficiency Testing. Die Arbeit nennt 46 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Application of College of American Pathologists (CAP) standards for molecular next-generation sequencing assays, typically high-complexity laboratory-developed tests, requires assay-specific, principled translation. We sought to systematically apply CAP laboratory-developed test validation requirements for next-generating sequencing to targeted CFTR gene sequencing on an Illumina iSeq100 Sequencing System and to address assay-specific translational guidance gaps.

Methods

We evaluated the analytic performance (accuracy, precision, analytic sensitivity, and specificity) and other requirements (eg, confirmatory testing, proficiency testing) in a CAP-accredited laboratory, including assessment of logistics (eg, turnaround time, cost), with particular attention to feasibility for smaller laboratories.

Results

Variant calls showed complete concordance across analytic parameters but, as the sole outcome measure, obscured subthreshold effects of experimental variables and random variability. Critical site depth analysis was essential to reveal these effects.

Discussion

Per-sample costs depend on batch size; smaller laboratories can reduce costs through centralization or sample pooling, although pooling requires longer turnaround (weeks to months), even on a iSeq100 system, potentially causing misalignment of CAP proficiency testing and batch schedules. This issue mandates self-evaluation and code 11 selection for CAP proficiency testing submissions. Real-time sample preparation, however, precludes running negative and internal controls with each processing run, necessitating process controls (eg, minor allele frequency, alternate allele determination) and an individualized quality control plan.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

High-Throughput Nucleotide SequencingAccreditationCystic Fibrosis Transmembrane Conductance RegulatorLaboratory Proficiency TestingLaboratories, ClinicalHumansLaboratories

Stichwörter der Autor:innen

CAPlaboratory-developed testvalidation

Substanzen

Cystic Fibrosis Transmembrane Conductance RegulatorCFTR protein, human

Autor:innen und Institutionen

  • Department of Pediatrics, Indus Hospital & Health Network, Karachi, Pakistan.
  • Molecular Pathology Section, Clinical Laboratories Indus Hospital & Health Network, Karachi, Pakistan.
  • Clinical Laboratories, Indus Hospital & Health Network, Lahore, Pakistan.

ORCID-Profile: Javeria Aijaz

Zitieren

APA

Fareeduddin, M., Usama, M., Hussain, S., Zahir, R. S. A., Sikander, N., & Aijaz, J. (2026). Operationalizing accreditation standards for laboratory-developed next-generation sequencing validation of CFTR amplicon-based assays. Laboratory Medicine, 57(5). https://doi.org/10.1093/labmed/lmag049

Vancouver

Fareeduddin M, Usama M, Hussain S, Zahir RSA, Sikander N, Aijaz J. Operationalizing accreditation standards for laboratory-developed next-generation sequencing validation of CFTR amplicon-based assays. Laboratory Medicine. 2026;57(5). doi:10.1093/labmed/lmag049

BibTeX
@article{Fareeduddin2026,
  author = {Fareeduddin, Muhammad and Usama, Muhammad and Hussain, Shakir and Zahir, Rukhsana Syed Aamir and Sikander, Nada and Aijaz, Javeria},
  title = {Operationalizing accreditation standards for laboratory-developed next-generation sequencing validation of CFTR amplicon-based assays},
  journal = {Laboratory Medicine},
  year = {2026},
  volume = {57},
  number = {5},
  doi = {10.1093/labmed/lmag049}
}
Kostenlos starten →