A protocol for autologous platelet-rich plasma collection using an automated blood cell separator: a retrospective study
Laboratory Medicine · 04.08.2026 · 57 (5)
DOI: 10.1093/labmed/lmag047 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Laboratory Medicine, online erschienen am 06.08.2026. Verfasst von Lei Shi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Transfusion Medicine, West China Hospital, West China Xiamen Hospital, Sichuan University, Xiamen Fujian, China. Hauptthemen laut MEDLINE: Platelet-Rich Plasma, Cell Separation. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
Introduction
Automated blood cell separators are commonly used for autologous platelet-rich plasma (PRP) preparation. Although these devices ensure stable platelet concentrations, low contamination, and high reproducibility, unified protocols remain lacking. This study explored a collection protocol that uses real-time visual feedback and dynamic parameter adjustment.
Methods
In this single-center retrospective study, we analyzed 35 autologous PRP collections. Visual criteria (pale lemon-yellow appearance, uniform turbidity, absence of macroscopically visible particles) and adjustment rules were developed. Platelet concentration, enrichment factor, and residual red blood cell (RBC) and white blood cell levels were assessed.
Results
Median platelet concentration was 1500 × 109/L (IQR, 1031-1618 × 109/L), and the mean (SD) enrichment factor was 6.33 (2.76); 71.43% (25/35) of products fell within a range of 1000 to 1800 × 109/L, consistent with reported 3-fold to 8-fold enrichment. Red blood cell counts ranged from 0 to 0.20 × 1012/L. No macroscopic RBCs were detected, but 37.1% (13/35) of RBCs exceeded a threshold of 0.05 × 1012/L. White blood cell counts ranged from 0 to 1.69 × 109/L, below the leukocyte-poor threshold proposed by Kikuchi et al.
Discussion
This study presented a protocol capable of producing PRP within the therapeutic range and achieving effective leukocyte control. Our findings provide a practical strategy for translating subjective experience into objective, trainable procedures. Given the limitations of small sample size and subjective visual criteria, further prospective machine vision validation is warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Transfusion Medicine, West China Hospital, West China Xiamen Hospital, Sichuan University, Xiamen Fujian, China.
- Department of Transfusion Medicine, West China Hospital, Sichuan University, Chengdu, China.
Zitieren
APA
Shi, L., Peng, L., Chen, L., Huang, Y., Wei, B., Ke, W., & Luo, Z. (2026). A protocol for autologous platelet-rich plasma collection using an automated blood cell separator: a retrospective study. Laboratory Medicine, 57(5). https://doi.org/10.1093/labmed/lmag047
Vancouver
Shi L, Peng L, Chen L, Huang Y, Wei B, Ke W, et al. A protocol for autologous platelet-rich plasma collection using an automated blood cell separator: a retrospective study. Laboratory Medicine. 2026;57(5). doi:10.1093/labmed/lmag047
BibTeX
@article{Shi2026,
author = {Shi, Lei and Peng, Lin and Chen, Lisheng and Huang, Ying and Wei, Bing and Ke, Weiting and Luo, Zhenglian},
title = {A protocol for autologous platelet-rich plasma collection using an automated blood cell separator: a retrospective study},
journal = {Laboratory Medicine},
year = {2026},
volume = {57},
number = {5},
doi = {10.1093/labmed/lmag047}
}
EUVIMED