Fachartikel in der Zeitschrift Laboratory Medicine, online erschienen am 10.06.2026. Verfasst von Jianbo Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Anatomy and Laboratory Medicine, West Virginia University, Morgantown, WV, United States. Hauptthemen laut MEDLINE: Comprehensive Metabolic Panel, Specimen Handling, Drug Contamination. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This study evaluated 5 methods for identifying intravenous fluid contamination in basic metabolic panel specimens.

Methods

Results for blood urea nitrogen, calcium, chloride, carbon dioxide, creatinine, glucose, potassium, and sodium were retrieved from metabolic panels tested in August 2025. All 5 methods were applied to 11 862 result sets with both preceding and subsequent results available within 48 hours. Chart review was conducted for all flagged specimens.

Results

The 5 methods collectively flagged 333 specimens, including 94 confirmed contaminations and 239 reflecting pathophysiologic changes or treatment effects. Alert rates ranged from 0.16% to 1.62%, and positive predictive values ranged from 23% to 100%. Among the 94 contaminated specimens, contaminants included 63 saline, 11 dextrose, 4 potassium, 5 PlasmaLyte A (Baxter) or lactated Ringer’s solution, and 11 other fluids. The methods showed differing sensitivities across contaminant types. False alerts were associated with diverse clinical conditions or therapeutic interventions, including kidney impairment, diabetes, hypokalemia, substantial infusion volumes, and recent calcium injections. The methods differed in the likelihood of false alerts.

Discussion

All 5 methods showed low alert rates with variable positive predictive values. Their performance is influenced by patient population characteristics. Local verification is essential before adopting externally developed methods for detecting specimen contaminations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Comprehensive Metabolic PanelSpecimen HandlingDrug ContaminationHumansAcademic Medical CentersSaline WatersGlucosePotassiumRinger's LactatePredictive Value of TestsElectrolytes

Stichwörter der Autor:innen

clinical chemistrydelta checkdetectionfalse alertintravenous fluidpreanalytical errorspecimen contamination

Substanzen

GlucosePotassiumPlasmalyte ARinger's LactateElectrolytes

Autor:innen und Institutionen

  • Department of Pathology, Anatomy and Laboratory Medicine, West Virginia University, Morgantown, WV, United States.
  • Department of Microbiology, Immunology and Cell Biology, West Virginia University, Morgantown, WV, United States.

ORCID-Profile: Jianbo Yang, Gangqing Hu, Danyel H Tacker

Zitieren

APA

Yang, J., Wang, L., Hu, G., & Tacker, D. H. (2026). Variable performance of 5 detection methods for identifying intravenous fluid contamination in basic metabolic panels at an academic medical center. Laboratory Medicine, 57(4). https://doi.org/10.1093/labmed/lmag034

Vancouver

Yang J, Wang L, Hu G, Tacker DH. Variable performance of 5 detection methods for identifying intravenous fluid contamination in basic metabolic panels at an academic medical center. Laboratory Medicine. 2026;57(4). doi:10.1093/labmed/lmag034

BibTeX
@article{Yang2026,
  author = {Yang, Jianbo and Wang, Lei and Hu, Gangqing and Tacker, Danyel H},
  title = {Variable performance of 5 detection methods for identifying intravenous fluid contamination in basic metabolic panels at an academic medical center},
  journal = {Laboratory Medicine},
  year = {2026},
  volume = {57},
  number = {4},
  doi = {10.1093/labmed/lmag034}
}
Kostenlos starten →