EUVIMEDEUVIMED entdecken
Crossref

Elevated methemoglobin levels in patients treated with high-dose hydroxocobalamin

Martinus Dyrud iD, Jianli Niu iD, Lisa Kohler

Laboratory Medicine · 2024

DOI: 10.1093/labmed/lmad037 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Laboratory Medicine, 2024. Verfasst von Martinus Dyrud und 2 weiteren Autor:innen. Beteiligte Einrichtung: Memorial Cardiac & Vascular Institute, Memorial Healthcare System, Hollywood, FL, US. Hauptthemen laut MEDLINE: Methemoglobin, Hydroxocobalamin. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of this study was to assess the impact of hydroxocobalamin (OHCbl) infusion on arterial blood gas and oximetry values in patients with vasoplegic syndrome.

Methods

Blood samples collected from 95 patients receiving OHCbl infusion were assayed using the ABL90 FLEX Plus blood gas analyzer for the concentration of methemoglobin (MetHb), total hemoglobin (tHb), carboxyhemoglobin (COHb), arterial oxygen saturation (SaO2), arterial oxygen partial pressure (PaO2), and arterial carbon dioxide partial pressure (PaCO2). Interference of OHCbl on these variables was evaluated using the measured difference between the preinfusion and postinfusion samples.

Results

Blood MetHb (%) measured after the infusion of OHCbl (5g) were significantly higher than the baseline levels, with a median of 4.8 (IQR, 3.0−6.5) versus 1.0 (IQR, 1.0−1.2) (P < .001). Blood COHb (%) increased from a median of 1.3 (IQR, 1.0−1.8) to 1.7 (IQR, 1.3−2.2) (P < .001) following the OHCbl infusion. No differences were seen in median levels of tHb, PaO2, PaCO2, and SaO2 between pre- and post-OHCbl treatment.

Conclusion

The presence of OHCbl in blood clearly interfered with the oximetry measurements of the hemoglobin component fractions by falsely increasing the levels of MetHb and COHb. Blood levels of MetHb and COHb cannot be reliably determined by the co-oximetry when OHCbl is known or suspected.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MethemoglobinHydroxocobalaminHumansHemoglobinsOximetryCarboxyhemoglobinOxygen

Stichwörter der Autor:innen

arterial blood gas analysiscarboxyhemoglobinhydroxocobalaminmethemoglobinoximetry assay

Substanzen

MethemoglobinHydroxocobalaminHemoglobinsCarboxyhemoglobinOxygen

Autor:innen und Institutionen

  • Memorial Cardiac & Vascular Institute, Memorial Healthcare System, Hollywood, FL, US.

ORCID-Profile: Martinus Dyrud, Jianli Niu

Zitieren

APA

Dyrud, M., Niu, J., & Kohler, L. (2024). Elevated methemoglobin levels in patients treated with high-dose hydroxocobalamin. Laboratory Medicine. https://doi.org/10.1093/labmed/lmad037

Vancouver

Dyrud M, Niu J, Kohler L. Elevated methemoglobin levels in patients treated with high-dose hydroxocobalamin. Laboratory Medicine. 2024. doi:10.1093/labmed/lmad037

BibTeX
@article{Dyrud2024,
  author = {Dyrud, Martinus and Niu, Jianli and Kohler, Lisa},
  title = {Elevated methemoglobin levels in patients treated with high-dose hydroxocobalamin},
  journal = {Laboratory Medicine},
  year = {2024},
  doi = {10.1093/labmed/lmad037}
}
Kostenlos starten →