EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Urine Protein Immunofixation Electrophoresis: Free Light Chain Urine Immunofixation Electrophoresis Is More Sensitive than Conventional Assays for Detecting Monoclonal Light Chains and Could Serve as a Marker of Minimal Residual Disease

Gurmukh Singh iD, Nkechi Arinze, David M Manthei, Frederick V Plapp, Roni J Bollag

Laboratory Medicine · 2023

DOI: 10.1093/labmed/lmac155 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Laboratory Medicine, 2023. Verfasst von Gurmukh Singh und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology Medical College of Georgia at Augusta University, Augusta, GA. Hauptthemen laut MEDLINE: Paraproteinemias, Multiple Myeloma, Monoclonal Gammopathy of Undetermined Significance. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Immunoglobulin monoclonal light chains (MLCs) in serum and urine are markers for monoclonal gammopathy and could serve as markers of minimal residual disease (MRD) in multiple myeloma (MM). Excretion of MLCs in urine is known to result in renal damage and shorter survival in patients with LC-predominant MM.

Methods

Retrospective review of urine immunofixation in 1738 specimens at 3 medical centers was conducted to assess the utility of urinalysis for diagnosis and monitoring of monoclonal gammopathy. We tested 228 stored urine specimens via the modified urine immunofixation method, using antisera to assay free LCs (FLCs).

Results

Our review of urine immunofixation results and medical records validated the theory that the only meaningful value-added finding was detection of monoclonal free light chains. Examination of 228 urine specimens using our novel method revealed 18.4% additional positive results. The rate of incremental findings for lambda LCs was nearly 3-fold higher than for kappa LCs.

Conclusions

The new method of urine immunofixation is significantly more sensitive and more efficient than the conventional method for detecting MLCs in urine. The new assay appears to be sensitive enough to prove that MLCs serve as a marker of MRD in MM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ParaproteinemiasMultiple MyelomaMonoclonal Gammopathy of Undetermined SignificanceHumansNeoplasm, ResidualImmunoglobulin Light ChainsElectrophoresisUrinalysisImmunoglobulin lambda-Chains

Stichwörter der Autor:innen

free light chain immunofixationminimal residual diseasemonoclonal gammopathymultiple myelomaserum free light chainurine immunofixation

Substanzen

Immunoglobulin Light ChainsImmunoglobulin lambda-Chains

Autor:innen und Institutionen

  • Department of Pathology Medical College of Georgia at Augusta University, Augusta, GA.
  • University of Michigan Ann Arbor, MI, and.
  • University of Kansas Medical Center, Kansas City, KS.

ORCID-Profile: Gurmukh Singh

Zitieren

APA

Singh, G., Arinze, N., Manthei, D. M., Plapp, F. V., & Bollag, R. J. (2023). Urine Protein Immunofixation Electrophoresis: Free Light Chain Urine Immunofixation Electrophoresis Is More Sensitive than Conventional Assays for Detecting Monoclonal Light Chains and Could Serve as a Marker of Minimal Residual Disease. Laboratory Medicine. https://doi.org/10.1093/labmed/lmac155

Vancouver

Singh G, Arinze N, Manthei DM, Plapp FV, Bollag RJ. Urine Protein Immunofixation Electrophoresis: Free Light Chain Urine Immunofixation Electrophoresis Is More Sensitive than Conventional Assays for Detecting Monoclonal Light Chains and Could Serve as a Marker of Minimal Residual Disease. Laboratory Medicine. 2023. doi:10.1093/labmed/lmac155

BibTeX
@article{Singh2023,
  author = {Singh, Gurmukh and Arinze, Nkechi and Manthei, David M and Plapp, Frederick V and Bollag, Roni J},
  title = {Urine Protein Immunofixation Electrophoresis: Free Light Chain Urine Immunofixation Electrophoresis Is More Sensitive than Conventional Assays for Detecting Monoclonal Light Chains and Could Serve as a Marker of Minimal Residual Disease},
  journal = {Laboratory Medicine},
  year = {2023},
  doi = {10.1093/labmed/lmac155}
}
Kostenlos starten →