Evaluation of RT-LAMP Assay for Rapid Detection of SARS-CoV-2
Laboratory Medicine · 2023
DOI: 10.1093/labmed/lmac030 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Laboratory Medicine, 2023. Verfasst von Ya-Ping Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China. Hauptthemen laut MEDLINE: SARS-CoV-2, COVID-19. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
To evaluate the accuracy of the reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in community or primary-care settings.
Method
We systematically searched the Web of Science, Embase, PubMed, and Cochrane Library databases. We conducted quality evaluation using ReviewManager software (version 5.0). We then used MetaDisc software (version 1.4) and Stata software (version 12.0) to build forest plots, along with a Deeks funnel plot and a bivariate boxplot for analysis.
Result
Overall, the sensitivity, specificity, and diagnostic odds ratio were 0.79, 0.97, and 328.18, respectively. The sensitivity for the subgroup with RNA extraction appeared to be higher, at 0.88 (0.86–0.90), compared to the subgroup without RNA extraction, at 0.50 (0.45–0.55), with no significant difference in specificity.
Conclusion
RT-LAMP assay exhibited high specificity regarding current SARS-CoV-2 infection. However, its overall sensitivity was relatively moderate. Extracting RNA was found to be beneficial in improving sensitivity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Laboratory Medicine, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
- Department of Clinical Medicine, The Second Clinical School of Guangzhou Medical University, Guangzhou, China.
- Department of Clinical Medicine, The Third Clinical School of Guangzhou Medical University, Guangzhou, China.
- Department of Clinical Medicine, The First Clinical School of Guangzhou Medical University, Guangzhou, China.
- Department of Chinese and Western Medicine in Clinical Medicine, The Clinical School of Chinese and Western Medicine of Guangzhou Medical University, Guangzhou, China.
- Guangdong Provincial Key Laboratory of Major Obstetric Diseases, The Third Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
Zitieren
APA
Li, Y. P., Cao, X. J., Luo, X., Xie, T. A., Liu, W. J., Xie, S. M., Lin, M., & Guo, X. G. (2023). Evaluation of RT-LAMP Assay for Rapid Detection of SARS-CoV-2. Laboratory Medicine. https://doi.org/10.1093/labmed/lmac030
Vancouver
Li YP, Cao XJ, Luo X, Xie TA, Liu WJ, Xie SM, et al. Evaluation of RT-LAMP Assay for Rapid Detection of SARS-CoV-2. Laboratory Medicine. 2023. doi:10.1093/labmed/lmac030