EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of low and high interstitial glucose concentrations in healthy, nondiabetic dogs using a flash glucose monitoring system

Rebecca F Brisman, Douglas A Palma, Philip R Fox

Journal of Veterinary Internal Medicine · 02.03.2026 · 40 (2)

DOI: 10.1093/jvimsj/aalag032 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Internal Medicine, online erschienen am 06.03.2026. Verfasst von Rebecca F Brisman und 2 weiteren Autor:innen. Beteiligte Einrichtung: The Schwarzman Animal Medical Center, New York, NY 10065, United States. Hauptthemen laut MEDLINE: Blood Glucose, Glucose. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Flash glucose monitoring systems (FGMS; FreeStyle Libre) are useful devices for managing diabetic patients. The FGMS is reportedly accurate for diabetic dogs with hyperglycemia and euglycemia but might underestimate glucose concentrations during hypoglycemia. Hypothesis/Objectives Assess the frequency of low and high interstitial glucose (IG) concentrations recorded in healthy, nondiabetic dogs using FGMS. Animals Twenty-three hospital employee-owned dogs.

Methods

Prospective, observational study. The FGMS was placed on all dogs to record ≥488 readings each over up to 14 days. Interstitial glucose concentrations were analyzed to identify the frequency of low, normal, and high IG concentrations. Descriptive statistics were calculated, and comparisons between demographic cohorts were performed.

Results

During monitoring, 73.7% (14/19) of participants had at least one low IG concentration (<70 mg/dL), whereas 26.3% (5/19) had at least one high IG concentration (>180 mg/dL). The mean (±SD) percentage of low and high IG concentrations per dog was 2.8 ± 4.3% and 0.8 ± 2.2%, respectively. Markedly decreased IG (<55 mg/dL) and markedly increased (>250 mg/dL) IG concentrations occurred in 63.2% (12/19) and 10.5% (2/19) of dogs, respectively. The frequency of low IG concentrations in dogs weighing 2.5-20.5 kg (2.2%; interquartile range [IQR], 1.1-5.0) was higher (P = .02) than in dogs weighing 20.6-41.4 kg (0.1%; IQR, 0.0-0.7%); the median difference was 2.1% (95% confidence interval, 0.6-10.1). Conclusions and clinical importance Low and high IG concentrations were recorded in healthy, nondiabetic dogs, providing a context for interpreting FGMS results in diabetic dogs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood GlucoseGlucoseAnimalsDogsFemaleContinuous Glucose MonitoringMaleProspective StudiesDog Diseases

Stichwörter der Autor:innen

caninediabetes mellitusfreestyle libreinterstitial glucose

Substanzen

Blood GlucoseGlucose

Autor:innen und Institutionen

  • The Schwarzman Animal Medical Center, New York, NY 10065, United States.

Zitieren

APA

Brisman, R. F., Palma, D. A., & Fox, P. R. (2026). Evaluation of low and high interstitial glucose concentrations in healthy, nondiabetic dogs using a flash glucose monitoring system. Journal of Veterinary Internal Medicine, 40(2). https://doi.org/10.1093/jvimsj/aalag032

Vancouver

Brisman RF, Palma DA, Fox PR. Evaluation of low and high interstitial glucose concentrations in healthy, nondiabetic dogs using a flash glucose monitoring system. Journal of Veterinary Internal Medicine. 2026;40(2). doi:10.1093/jvimsj/aalag032

BibTeX
@article{Brisman2026,
  author = {Brisman, Rebecca F and Palma, Douglas A and Fox, Philip R},
  title = {Evaluation of low and high interstitial glucose concentrations in healthy, nondiabetic dogs using a flash glucose monitoring system},
  journal = {Journal of Veterinary Internal Medicine},
  year = {2026},
  volume = {40},
  number = {2},
  doi = {10.1093/jvimsj/aalag032}
}
Kostenlos starten →