Inflatable penile prostheses long-term revision and removal rates compared to semi-rigid penile prostheses: a real-world analysis from a global electronic health record (EHR) database
The Journal of Sexual Medicine · 2026
DOI: 10.1093/jsxmed/qdag034 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift The Journal of Sexual Medicine, 2026. Verfasst von Sarah Kohl und 7 weiteren Autor:innen. Beteiligte Einrichtung: Robert Larner College of Medicine, The University of Vermont, Burlington, VT 05405, United States. Hauptthemen laut MEDLINE: Penile Prosthesis, Reoperation, Penile Implantation, Device Removal. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
Background
Reoperation rates following penile prosthesis implantation are influenced by patient- and device-related factors. While previous studies from high-volume centers have reported 5 to 10-year reoperation rates of 11%-16%, these findings may not fully capture outcomes in broader, real-world populations.
Aim
This study aimed to assess long-term complication and reoperation rates for penile prostheses using a global electronic health records database.
Methods
We conducted a retrospective observational analysis using electronic health records and insurance claims from the TriNetX Global Health Research Network, covering May 2005 to May 2025. Men aged 18-90 who underwent initial implantation of either an inflatable or semi-rigid penile prosthesis (SRPP) were included. Statistical comparisons between cohorts used two-sample Z-tests, with significance set at P < .05. Outcomes Outcomes included device revision or reimplantation, explantation, infection, mechanical failure, and displacement.
Results
Among 29 385 men, 18 749 received inflatable prostheses and 10 636 received semi-rigid devices. At 5 years, the revision/removal rate was not significantly lower for inflatable devices (13.9%) compared to semi-rigid implants (13.7%; P < .77). Total explantation rates were lower for inflatable prostheses at 5 years (6.5% vs. 8.4%, P < .00001). Mechanical breakdown was more common in the inflatable cohort at 5 years (9.1% vs. 6.7%; P ≤ .0001). There was also a significantly higher rate of device displacement for inflatable prostheses at 5 years (2.3% vs. 1.6%; P = .002). There were no differences in infection rates between devices over time. Clinical Implications This analysis found that inflatable penile prostheses (IPPs) are associated with similar long-term revision and lower explantation rates compared to semi-rigid devices, but more prone to mechanical breakdown and displacement. These findings support the use of inflatable prostheses in appropriate patients seeking lower rates of device removal and underscore the importance of real-world data in surgical decision-making. Strengths & Limitations The strengths of this study include its large sample size, applicability, and the use of a global clinical dataset integrating claims and electronic health record data to reduce missing information. However, several limitations should be acknowledged. TriNetX does not account for variation in surgical technique, device manufacturer, or surgeon experience. In addition, reliance on administrative codes may underreport complications or omit clinical nuances. Retrospective and observational studies are also limited by inherent biases, incomplete data, and inability to establish causality, which constrain the interpretation.
Conclusion
In this large-scale, real-world analysis, IPPs were associated with similar long-term revision and significantly lower removal rates compared to SRPPs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Robert Larner College of Medicine, The University of Vermont, Burlington, VT 05405, United States.
- Division of Urology, University of Vermont Medical Center, Burlington, VT 05405, United States.
ORCID-Profile: Sarah Kohl, Richard Grunert
Zitieren
APA
Kohl, S., Goebel, C., Kuzina, A., Rubin, B., Bleau, J., Mann-Gow, T., Mohaghegh, M., & Grunert, R. (2026). Inflatable penile prostheses long-term revision and removal rates compared to semi-rigid penile prostheses: a real-world analysis from a global electronic health record (EHR) database. The Journal of Sexual Medicine. https://doi.org/10.1093/jsxmed/qdag034
Vancouver
Kohl S, Goebel C, Kuzina A, Rubin B, Bleau J, Mann-Gow T, et al. Inflatable penile prostheses long-term revision and removal rates compared to semi-rigid penile prostheses: a real-world analysis from a global electronic health record (EHR) database. The Journal of Sexual Medicine. 2026. doi:10.1093/jsxmed/qdag034
BibTeX
@article{Kohl2026,
author = {Kohl, Sarah and Goebel, Clara and Kuzina, Angelina and Rubin, Benjamin and Bleau, Jacob and Mann-Gow, Travis and Mohaghegh, Mohammad and Grunert, Richard},
title = {Inflatable penile prostheses long-term revision and removal rates compared to semi-rigid penile prostheses: a real-world analysis from a global electronic health record (EHR) database},
journal = {The Journal of Sexual Medicine},
year = {2026},
doi = {10.1093/jsxmed/qdag034}
}
EUVIMED