Deep learning-based dose prediction in proton beam therapy for hepatocellular carcinoma: comparison of network architectures and loss functions
Journal of Radiation Research · 26.05.2026 · 67 (3) · 369-383
DOI: 10.1093/jrr/rrag026 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Radiation Research, online erschienen am 06.05.2026. Verfasst von Shuta Ogawa und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, 7-172 Yatsuyamada, Koriyama, Fukushima, 963-8052, Japan. Hauptthemen laut MEDLINE: Liver Neoplasms, Deep Learning, Carcinoma, Hepatocellular, Proton Therapy. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
In proton beam therapy (PBT) for hepatocellular carcinoma (HCC), deep learning (DL)-based dose prediction offers clinical value by providing immediate reference dose distributions as a guideline tool for treatment planners and enabling virtual PBT dose assessment at institutions lacking PBT facilities to support clinical decision-making. This study proposes a dose gradient-aware DL training approach and a beam arrangement-free framework that predicts dose distributions from computed tomography (CT) images and target/organs-at-risk structures without requiring beam arrangement inputs. Using data from 172 HCC patients, we systematically compared 20 DL models combining five architectures with four loss functions, including a novel dose gradient-aware loss capturing PBT-specific dose distribution characteristics arising from the Bragg peak. Prediction accuracy was evaluated using dose metrics for clinical target volume, planning target volume, and normal liver, 10% dose region volume assessment, visual examination, Dice similarity coefficient (DSC) for 10% dose region, and dose–volume histogram (DVH) analysis. DL models employing dose gradient-aware loss demonstrated reduced prediction errors in target volume dose metrics, achieved the lowest errors in 10% dose region volume when combined with U-Net (MAE: 35.4 cm3, RMSE: 51.3 cm3), attained the highest DSC (0.88 ± 0.05), showed the closest DVH agreement with clinical plans for both target structures and normal liver. A comprehensive evaluation consistently confirmed the superiority of dose gradient-aware loss across all metrics, demonstrating the importance of physics-informed, dose gradient-aware learning for accurate PBT dose distribution prediction. Particularly, DL models combining simple architectures with dose gradient-aware loss predicted doses that closely approximated clinical doses in PBT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Physics and Technology, Southern Tohoku Proton Therapy Center, 7-172 Yatsuyamada, Koriyama, Fukushima, 963-8052, Japan.
- Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryou-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima, Fukushima, 960-8516, Japan.
- Department of Therapeutic Radiology, University of Yamanashi, 1110 Shimokato, Chuo-city, Yamanashi, 409-3898, Japan.
- Department of Radiation Oncology, Southern Tohoku Proton Therapy Center, 7-172 Yatsuyamada, Koriyama, Fukushima, 963-8052, Japan.
ORCID-Profile: Shuta Ogawa, Noriyuki Kadoya, Takahiro Kato, Ryohei Kato, Yuki Narita, Masao Murakami, Keiichi Jingu
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Ogawa, S., Kadoya, N., Kato, T., Kato, R., Tozuka, R., Narita, Y., Oyama, S., Murakami, M., & Jingu, K. (2026). Deep learning-based dose prediction in proton beam therapy for hepatocellular carcinoma: comparison of network architectures and loss functions. Journal of Radiation Research, 67(3), 369-383. https://doi.org/10.1093/jrr/rrag026
Vancouver
Ogawa S, Kadoya N, Kato T, Kato R, Tozuka R, Narita Y, et al. Deep learning-based dose prediction in proton beam therapy for hepatocellular carcinoma: comparison of network architectures and loss functions. Journal of Radiation Research. 2026;67(3):369-383. doi:10.1093/jrr/rrag026
BibTeX
@article{Ogawa2026,
author = {Ogawa, Shuta and Kadoya, Noriyuki and Kato, Takahiro and Kato, Ryohei and Tozuka, Ryota and Narita, Yuki and Oyama, Sho and Murakami, Masao and Jingu, Keiichi},
title = {Deep learning-based dose prediction in proton beam therapy for hepatocellular carcinoma: comparison of network architectures and loss functions},
journal = {Journal of Radiation Research},
year = {2026},
volume = {67},
number = {3},
pages = {369--383},
doi = {10.1093/jrr/rrag026}
}
EUVIMED