Fachartikel in der Zeitschrift Journal of Radiation Research, 2023. Verfasst von Mitsuhiro Kon und 16 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan. Hauptthemen laut MEDLINE: Radiotherapy, Conformal, Radiosurgery, Prostatic Neoplasms, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Ministry of Education, Culture, Sports, Science and Technology, National Cancer Center Research and Development Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to clarify the differences in radiotherapy dose characteristics and delivery efficiency between the supine and prone positions in patients with prostate cancer using the CyberKnife. The planning computed tomography (CT) and delineations of the prone position were obtained by rotating the supine CT images with delineations of 180° using image processing software. The optimization parameters for planning target volume (PTV) and organs at risk (OARs) were based on the prone position. The optimization parameters determined for the prone position were applied to the supine position for optimization and dose calculation. The dosimetric characteristics of the PTV and OARs, and delivery efficiency were compared between the two different patient positions. The plans in the prone position resulted in better PTV conformity index (nCI), rectum V90%, V80%, V75%, V50% and bladder V50%. A significant difference was observed in treatment time and depth along the central axis (dCAX) between the two plans. The mean treatment time per fraction and dCAX for the supine and prone positions were 20.9 ± 1.7 min versus 19.8 ± 1.3 min (P = 0.019) and 151.1 ± 33.6 mm versus 233.2 ± 8.8 mm (P < 0.001), respectively. In this study the prone position was found to improve dosimetric characteristics and delivery efficiency compared with the supine position during prostate cancer treatment with the CyberKnife.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, ConformalRadiosurgeryProstatic NeoplasmsRadiotherapy, Intensity-ModulatedMaleHumansProstateRadiotherapy Planning, Computer-AssistedSupine PositionRadiotherapy DosageOrgans at RiskProne Position

Stichwörter der Autor:innen

CyberKnifeSBRTprone positionprostate cancersupine position

Autor:innen und Institutionen

  • Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan.
  • Department of Radiological Technology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan.
  • Faculty of Health Sciences, Hokkaido University, North12, West5, Kita-ku, Sapporo, Hokkaido 060-0812, Japan.
  • Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku Tokyo, 104-0045, Japan.

Förderung

  • Ministry of Education, Culture, Sports, Science and Technology
  • National Cancer Center Research and Development Fund

Zitieren

APA

Kon, M., Okamoto, H., Nakamura, S., Iijima, K., Chiba, T., Takemori, M., Nakayama, H., Nakaichi, T., Mikasa, S., Fujii, K., Urago, Y., Ishikawa, M., Sofue, T., Katsuta, S., Inaba, K., Igaki, H., & Aso, T. (2023). Planning study: prone versus supine position for stereotactic body radiotherapy in prostate by CyberKnife. Journal of Radiation Research. https://doi.org/10.1093/jrr/rrac065

Vancouver

Kon M, Okamoto H, Nakamura S, Iijima K, Chiba T, Takemori M, et al. Planning study: prone versus supine position for stereotactic body radiotherapy in prostate by CyberKnife. Journal of Radiation Research. 2023. doi:10.1093/jrr/rrac065

BibTeX
@article{Kon2023,
  author = {Kon, Mitsuhiro and Okamoto, Hiroyuki and Nakamura, Satoshi and Iijima, Kotaro and Chiba, Takahito and Takemori, Mihiro and Nakayama, Hiroki and Nakaichi, Tetsu and Mikasa, Shohei and Fujii, Kyohei and Urago, Yuka and Ishikawa, Masayori and Sofue, Toshimitsu and Katsuta, Shoichi and Inaba, Koji and Igaki, Hiroshi and Aso, Tomohiko},
  title = {Planning study: prone versus supine position for stereotactic body radiotherapy in prostate by CyberKnife},
  journal = {Journal of Radiation Research},
  year = {2023},
  doi = {10.1093/jrr/rrac065}
}
Kostenlos starten →