EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamic scan shaping: overcoming coil hysteresis for high-speed STEM

Jonathan J P Peters, Grigore Moldovan, Lewys Jones

Microscopy · 12.05.2026

DOI: 10.1093/jmicro/dfag025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy, online erschienen am 12.05.2026. Verfasst von Jonathan J P Peters und 2 weiteren Autor:innen. Beteiligte Einrichtung: Advanced Microscopy Laboratory, CRANN, Trinity College Dublin, the University of Dublin. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Ireland.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Scanning transmission electron microscopy (STEM) has a number of benefits over conventional parallel illumination transmission electron microscopy, such as the ability to simultaneously perform a range of imaging and spectroscopy techniques. However, one distinct disadvantage is the slow imaging speeds, a consequence of the sequential nature of the pixel acquisition, limiting imaging speeds to a few frames per second (fps). This reduces dose-rate control, increases the effect of distortions and hinders the ability to capture dynamic events for in situ experiments. The main obstacle to faster framerates is the inductance and hysteresis of the scanning coils, which have previously only been addressable with the addition of entirely new hardware coils. Here we demonstrate a predictive scan shaping approach using conventional scanning systems, where scan input is determined based on where the beam will be instead of where the beam should be. We use this new approach to acquire fully sampled 512 × 512 images at 60 ns per pixel, giving a frame rate of 41 fps.

Schlagwörter

Stichwörter der Autor:innen

STEMbeam controlhigh speed imagingin-situscan shapingscanning

Autor:innen und Institutionen

  • Advanced Microscopy Laboratory, CRANN, Trinity College Dublin, the University of Dublin.
  • School of Physics, Trinity College Dublin, the University of Dublin.
  • point electronic GmbH, Halle (Saale), Germany.

Förderung

  • Research Ireland

Zitieren

APA

Peters, J. J. P., Moldovan, G., & Jones, L. (2026). Dynamic scan shaping: overcoming coil hysteresis for high-speed STEM. Microscopy. https://doi.org/10.1093/jmicro/dfag025

Vancouver

Peters JJP, Moldovan G, Jones L. Dynamic scan shaping: overcoming coil hysteresis for high-speed STEM. Microscopy. 2026. doi:10.1093/jmicro/dfag025

BibTeX
@article{Peters2026,
  author = {Peters, Jonathan J P and Moldovan, Grigore and Jones, Lewys},
  title = {Dynamic scan shaping: overcoming coil hysteresis for high-speed STEM},
  journal = {Microscopy},
  year = {2026},
  doi = {10.1093/jmicro/dfag025}
}
Kostenlos starten →