Resolution improvement of differential phase-contrast microscopy via tilt-series acquisition for environmental cell application
Microscopy · 31.03.2025 · 74 (2) · 92-97
DOI: 10.1093/jmicro/dfae049 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microscopy, online erschienen am 16.10.2024. Verfasst von Kazutaka Mitsuishi und 6 weiteren Autor:innen. Beteiligte Einrichtung: National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047, Japan. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 19 Literaturangaben. Gefördert von: Innovative Science and Technology Initiative for Security.
Abstract (Originalsprache)
A simple method that improves the resolution of phase measurement in differential phase-contrast scanning transmission electron microscopy for closed-type environmental cell applications was developed and tested using a model sample simulating environmental cell observations. Because the top and bottom membranes of an environmental cell are typically far apart, the images from these membranes are shifted widely by tilt-series acquisition, and averaging the images after alignment can effectively eliminate undesired signals from the membranes while improving the signal from the object of interest. It was demonstrated that a phase precision of 2π/100 rad is well achievable using the proposed method for the sample in an environmental cell.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047, Japan.
- Research and Development Group, Hitachi, Ltd, 2520 Akanuma, Hatoyama, Saitama 350-0395, Japan.
ORCID-Profile: Kazutaka Mitsuishi, Fumiaki Ichihashi, Yoshio Takahashi, Katsuaki Nakazawa, Masaki Takeguchi, Toshiaki Tanigaki
Förderung
- Innovative Science and Technology Initiative for Security
Zitieren
APA
Mitsuishi, K., Ichihashi, F., Takahashi, Y., Nakazawa, K., Takeguchi, M., Hashimoto, A., & Tanigaki, T. (2025). Resolution improvement of differential phase-contrast microscopy via tilt-series acquisition for environmental cell application. Microscopy, 74(2), 92-97. https://doi.org/10.1093/jmicro/dfae049
Vancouver
Mitsuishi K, Ichihashi F, Takahashi Y, Nakazawa K, Takeguchi M, Hashimoto A, et al. Resolution improvement of differential phase-contrast microscopy via tilt-series acquisition for environmental cell application. Microscopy. 2025;74(2):92-97. doi:10.1093/jmicro/dfae049
BibTeX
@article{Mitsuishi2025,
author = {Mitsuishi, Kazutaka and Ichihashi, Fumiaki and Takahashi, Yoshio and Nakazawa, Katsuaki and Takeguchi, Masaki and Hashimoto, Ayako and Tanigaki, Toshiaki},
title = {Resolution improvement of differential phase-contrast microscopy via tilt-series acquisition for environmental cell application},
journal = {Microscopy},
year = {2025},
volume = {74},
number = {2},
pages = {92--97},
doi = {10.1093/jmicro/dfae049}
}
EUVIMED