EUVIMEDEUVIMED entdecken
Crossref

Improving the depth resolution of STEM-ADF sectioning by 3D deconvolution

A Ishizuka, K Ishizuka, R Ishikawa, N Shibata, Y Ikuhara, H Hashiguchi, R Sagawa

Microscopy · 24.03.2021 · 70 (2) · 241-249

DOI: 10.1093/jmicro/dfaa056 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy, online erschienen am 13.10.2020. Verfasst von A Ishizuka und 6 weiteren Autor:innen. Beteiligte Einrichtung: HREM Research Inc., 14-48 Matsukazedai, Higashimatsuyama, Saitama, Japan. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Although the possibility of locating single atom in three dimensions using the scanning transmission electron microscope (STEM) has been discussed with the advent of aberration correction technology, it is still a big challenge. In this report we have developed deconvolution routines based on maximum entropy method (MEM) and Richardson–Lucy algorithm (RLA), which are applicable to the STEM-annular dark-field (ADF) though-focus images to improve the depth resolution. The new three-dimensional (3D) deconvolution routines require a limited defocus-range of STEM-ADF images that covers a whole sample and some vacuum regions. Since the STEM-ADF probe is infinitely elongated along the optical axis, a 3D convolution is performed with a two-dimensional (2D) convolution over xy-plane using the 2D fast Fourier transform in reciprocal space, and a one-dimensional convolution along the z-direction in real space. Using our new deconvolution routines, we have processed simulated focal series of STEM-ADF images for single Ce dopants embedded in wurtzite-type AlN. Applying the MEM, the Ce peaks are clearly localized along the depth, and the peak width is reduced down to almost one half. We also applied the new deconvolution routines to experimental focal series of STEM-ADF images of a monolayer graphene. The RLA gives smooth and high-P/B ratio scattering distribution, and the graphene layer can be easily detected. Using our deconvolution algorithms, we can determine the depth locations of the heavy dopants and the graphene layer within the precision of 0.1 and 0.2 nm, respectively. Thus, the deconvolution must be extremely useful for the optical sectioning with 3D STEM-ADF images.

Schlagwörter

Stichwörter der Autor:innen

3D deconvolutionRichardson–Lucy algorithmSTEM-ADFdepth resolutionmaximum entropy method (MEM)optical sectioning

Autor:innen und Institutionen

  • HREM Research Inc., 14-48 Matsukazedai, Higashimatsuyama, Saitama, Japan.
  • Institute of Engineering Innovation, University of Tokyo, 2-11-16 Yayoi, Bunkyo, Tokyo, Japan.
  • PRESTO, Japan Science and Technology Agency, 4-1-8, Honcho, Kawaguchi, Saitama, Japan.
  • Nanostructures Research Laboratory, Japan Fine Ceramics Center, Nagoya, Aichi, Japan.
  • JEOL Ltd, 3-1-2 Musashino, Akishima, Tokyo, Japan.

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Ishizuka, A., Ishizuka, K., Ishikawa, R., Shibata, N., Ikuhara, Y., Hashiguchi, H., & Sagawa, R. (2021). Improving the depth resolution of STEM-ADF sectioning by 3D deconvolution. Microscopy, 70(2), 241-249. https://doi.org/10.1093/jmicro/dfaa056

Vancouver

Ishizuka A, Ishizuka K, Ishikawa R, Shibata N, Ikuhara Y, Hashiguchi H, et al. Improving the depth resolution of STEM-ADF sectioning by 3D deconvolution. Microscopy. 2021;70(2):241-249. doi:10.1093/jmicro/dfaa056

BibTeX
@article{Ishizuka2021,
  author = {Ishizuka, A and Ishizuka, K and Ishikawa, R and Shibata, N and Ikuhara, Y and Hashiguchi, H and Sagawa, R},
  title = {Improving the depth resolution of STEM-ADF sectioning by 3D deconvolution},
  journal = {Microscopy},
  year = {2021},
  volume = {70},
  number = {2},
  pages = {241--249},
  doi = {10.1093/jmicro/dfaa056}
}
Kostenlos starten →