Improved 13C metabolic flux analysis in Escherichia coli metabolism: application of a high-resolution MS (GC–EI–QTOF) for comprehensive assessment of MS/MS fragments
Journal of Industrial Microbiology and Biotechnology · 17.02.2023 · 50 (1)
DOI: 10.1093/jimb/kuad039 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Industrial Microbiology and Biotechnology, online erschienen am 13.11.2023. Verfasst von Chris Richter und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Hoher Weg 8, D-06120Halle (Saale), Germany. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Escherichia coli. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Gas chromatography–tandem mass spectrometry with electron ionization (GC–EI–MS/MS) provides rich information on stable-isotope labeling for 13C-metabolic flux analysis (13C-MFA). To pave the way for the routine application of tandem MS data for metabolic flux quantification, we aimed to compile a comprehensive library of GC–EI–MS/MS fragments of tert-butyldimethylsilyl (TBDMS) derivatized proteinogenic amino acids. First, we established an analytical workflow that combines high-resolution gas chromatography-quadrupole time-of-flight mass spectrometry and fully 13C-labeled biomass to identify and structurally elucidate tandem MS amino acid fragments. Application of the high-mass accuracy MS procedure resulted into the identification of 129 validated precursor–product ion pairs of 13 amino acids with 30 fragments being accepted for 13C-MFA. The practical benefit of the novel tandem MS data was demonstrated by a proof–of–concept study, which confirmed the importance of the compiled library for high-resolution 13C-MFA. One sentence summary An analytical workflow that combines high-resolution mass spectrometry (MS) and fully 13C-labeled biomass to identify and structurally elucidate tandem MS amino acid fragments, which provide positional information and therefore offering significant advantages over traditional MS to improve 13C-metabolic flux analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Pharmacy, Martin Luther University Halle-Wittenberg, Hoher Weg 8, D-06120Halle (Saale), Germany.
- Leibniz Institute of Plant Biochemistry, Weinberg 3, D-06120Halle (Saale), Germany.
ORCID-Profile: Chris Richter, Eva Grafahrend-Belau, Manish L Raorane, Björn H Junker
Zitieren
APA
Richter, C., Grafahrend-Belau, E., Ziegler, J., Raorane, M. L., & Junker, B. H. (2023). Improved 13C metabolic flux analysis in Escherichia coli metabolism: application of a high-resolution MS (GC–EI–QTOF) for comprehensive assessment of MS/MS fragments. Journal of Industrial Microbiology and Biotechnology, 50(1). https://doi.org/10.1093/jimb/kuad039
Vancouver
Richter C, Grafahrend-Belau E, Ziegler J, Raorane ML, Junker BH. Improved 13C metabolic flux analysis in Escherichia coli metabolism: application of a high-resolution MS (GC–EI–QTOF) for comprehensive assessment of MS/MS fragments. Journal of Industrial Microbiology and Biotechnology. 2023;50(1). doi:10.1093/jimb/kuad039
BibTeX
@article{Richter2023,
author = {Richter, Chris and Grafahrend-Belau, Eva and Ziegler, Jörg and Raorane, Manish L and Junker, Björn H},
title = {Improved 13C metabolic flux analysis in Escherichia coli metabolism: application of a high-resolution MS (GC–EI–QTOF) for comprehensive assessment of MS/MS fragments},
journal = {Journal of Industrial Microbiology and Biotechnology},
year = {2023},
volume = {50},
number = {1},
doi = {10.1093/jimb/kuad039}
}
EUVIMED