Time to Enhancement Measured From Ultrafast Dynamic Contrast-Enhanced MRI for Improved Breast Lesion Diagnosis
Journal of Breast Imaging · 2025
DOI: 10.1093/jbi/wbae089 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Breast Imaging, 2025. Verfasst von Yun An Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Washington, Seattle, WA, USA. Hauptthemen laut MEDLINE: Contrast Media, Magnetic Resonance Imaging, Breast Neoplasms, Image Enhancement. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Cancer Institute.
Abstract (Originalsprache)
Objective
Breast MRI affords high sensitivity with intermediate specificity for cancer detection. Ultrafast dynamic contrast-enhanced (DCE) MRI assesses early contrast inflow with potential to supplement or replace conventional DCE-MRI kinetic features. We sought to determine whether radiologist’s evaluation of ultrafast DCE-MRI can increase specificity of a clinical MRI protocol.
Methods
In this IRB-approved, HIPAA-compliant study, breast MRIs from March 2019 to August 2020 with a BI-RADS category 3, 4, or 5 lesion were identified. Ultrafast DCE-MRI was acquired during the first 40 seconds after contrast injection and before conventional DCE-MRI postcontrast acquisitions in the clinical breast MRI protocol. Three radiologists masked to outcomes retrospectively determined lesion time to enhancement (TTE) on ultrafast DCE-MRI. Interreader agreement, differences between benign and malignant lesion TTE, and TTE diagnostic performance were evaluated.
Results
Ninety-five lesions (20 malignant, 75 benign) were included. Interreader agreement in TTE was moderate to substantial for both ultrafast source images and subtraction maximum intensity projections (overall κ = 0.63). Time to enhancement was greater across benign lesions compared with malignancies (P <.05), and all lesions demonstrating no enhancement during the ultrafast series were benign. With a threshold TTE ≥40 seconds, ultrafast DCE-MRI yielded an average 40% specificity (95% CI, 30%-48%) and 92% sensitivity (95% CI, 81%-100%), yielding a potential reduction in 31% (95% CI, 23%-39%) of benign follow-ups based on conventional DCE-MRI.
Conclusion
Ultrafast imaging can be added to conventional DCE-MRI to increase diagnostic accuracy while adding minimal scan time. Future work to standardize evaluation criteria may improve interreader agreement and allow for more robust ultrafast DCE-MRI assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, University of Washington, Seattle, WA, USA.
- Clinical Research Division, Fred Hutchinson Cancer Center, Seattle, Washington, USA.
- Department of Radiology, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
ORCID-Profile: Anum S Kazerouni, Daniel S Hippe, Habib Rahbar
Förderung
- NCI NIH HHS
- National Cancer Institute
Zitieren
APA
Chen, Y. A., Kazerouni, A. S., Phelps, M. D., Hippe, D. S., Youn, I., Lee, J. M., Partridge, S. C., & Rahbar, H. (2025). Time to Enhancement Measured From Ultrafast Dynamic Contrast-Enhanced MRI for Improved Breast Lesion Diagnosis. Journal of Breast Imaging. https://doi.org/10.1093/jbi/wbae089
Vancouver
Chen YA, Kazerouni AS, Phelps MD, Hippe DS, Youn I, Lee JM, et al. Time to Enhancement Measured From Ultrafast Dynamic Contrast-Enhanced MRI for Improved Breast Lesion Diagnosis. Journal of Breast Imaging. 2025. doi:10.1093/jbi/wbae089
BibTeX
@article{Chen2025,
author = {Chen, Yun An and Kazerouni, Anum S and Phelps, Matthew D and Hippe, Daniel S and Youn, Inyoung and Lee, Janie M and Partridge, Savannah C and Rahbar, Habib},
title = {Time to Enhancement Measured From Ultrafast Dynamic Contrast-Enhanced MRI for Improved Breast Lesion Diagnosis},
journal = {Journal of Breast Imaging},
year = {2025},
doi = {10.1093/jbi/wbae089}
}
EUVIMED