Fachartikel in der Zeitschrift Journal of Breast Imaging, 2025. Verfasst von Alyssa T Watanabe und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Southern California Keck School of Medicine, Los Angeles, CA, USA. Hauptthemen laut MEDLINE: Mammography, Artificial Intelligence, Vascular Calcification, Breast. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CureMetrix, Inc.
Abstract (Originalsprache)
Objective
The performance of a commercially available artificial intelligence (AI)–based software that detects breast arterial calcifications (BACs) on mammograms is presented.
Methods
This retrospective study was exempt from IRB approval and adhered to the HIPAA regulations. Breast arterial calcification detection using AI was assessed in 253 patients who underwent 314 digital mammography (DM) examinations and 143 patients who underwent 277 digital breast tomosynthesis (DBT) examinations between October 2004 and September 2022. Artificial intelligence performance for binary BAC detection was compared with ground truth (GT) determined by the majority consensus of breast imaging radiologists. Area under the receiver operating curve (AUC), sensitivity, specificity, positive predictive value and negative predictive value (NPV), accuracy, and BAC prevalence rates of the AI algorithm were compared.
Results
The case-level AUCs of AI were 0.96 (0.93-0.98) for DM and 0.95 (0.92-0.98) for DBT. Sensitivity, specificity, and accuracy were 87% (79%-93%), 92% (88%-96%), and 91% (87%-94%) for DM and 88% (80%-94%), 90% (84%-94%), and 89% (85%-92%) for DBT. Positive predictive value and NPV were 82% (72%-89%) and 95% (92%-97%) for DM and 84% (76%-90%) and 92% (88%-96%) for DBT, respectively. Results are 95% confidence intervals. Breast arterial calcification prevalence was similar for both AI and GT assessments.
Conclusion
Breast AI software for detection of BAC presence on mammograms showed promising performance for both DM and DBT examinations. Artificial intelligence has potential to aid radiologists in detection and reporting of BAC on mammograms, which is a known cardiovascular risk marker specific to women.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of Southern California Keck School of Medicine, Los Angeles, CA, USA.
- CureMetrix Inc, San Diego, CA, USA.
- Department of Diagnostic Radiology, Harbor UCLA Medical Center, Torrance, CA, USA.
- Bedford Breast Center, Beverly Hills, CA, USA.
- Victorian Heart Institute & Monash Health Heart, Victorian Heart Hospital, Monash University, Clayton, VIC, Australia.
- Baker Heart and Diabetes Institute, Melbourne, VIC, Australia.
ORCID-Profile: Alyssa T Watanabe, Valerie Dib
Förderung
- CureMetrix, Inc
Zitieren
APA
Watanabe, A. T., Dib, V., Wang, J., Mantey, R., Daughton, W., Chim, C. Y., Eckel, G., Moss, C., Goel, V., & Nerlekar, N. (2025). Artificial Intelligence–based Software for Breast Arterial Calcification Detection on Mammograms. Journal of Breast Imaging. https://doi.org/10.1093/jbi/wbae064
Vancouver
Watanabe AT, Dib V, Wang J, Mantey R, Daughton W, Chim CY, et al. Artificial Intelligence–based Software for Breast Arterial Calcification Detection on Mammograms. Journal of Breast Imaging. 2025. doi:10.1093/jbi/wbae064
BibTeX
@article{Watanabe2025,
author = {Watanabe, Alyssa T and Dib, Valerie and Wang, Junhao and Mantey, Richard and Daughton, William and Chim, Chi Yung and Eckel, Gregory and Moss, Caroline and Goel, Vinay and Nerlekar, Nitesh},
title = {Artificial Intelligence–based Software for Breast Arterial Calcification Detection on Mammograms},
journal = {Journal of Breast Imaging},
year = {2025},
doi = {10.1093/jbi/wbae064}
}
EUVIMED