Skin Graft Thickness Consistency: A Comparison of Traditional Dermatome and Rotating Circular Blade Technology
Journal of Burn Care & Research · 14.11.2026
DOI: 10.1093/jbcr/irag184 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Burn Care & Research, online erschienen am 14.11.2026. Verfasst von Timothy Worley und 6 weiteren Autor:innen. Beteiligte Einrichtung: Texas Tech University Health Sciences Center, School of Medicine, Lubbock, TX, USA.
Abstract (Originalsprache)
Our objective was to evaluate the accuracy and intra-graft consistency of split-thickness skin graft thickness using a traditional dermatome versus a dermatome with a rotating circular blade. A controlled cadaveric study was conducted with operators across four experience levels. Each participant harvested split-thickness skin grafts using both devices set to 0.009 inches (0.229 mm). Grafts were obtained from adjacent locations on the back and leg. Three 6-mm punch biopsies per graft were analyzed histologically for thickness. Outcomes included deviation from the depth setting and intra-graft variability. Statistical comparisons included independent t-tests and analysis of variance. A total of 118 samples were analyzed. Traditional dermatome grafts were significantly thicker than intended (mean 0.0119 inches (0.30 mm); +33%), whereas grafts taken with the rotating circular blade dermatome were closer to target (mean 0.0080 inches [0.20 mm]; −11%) (p = 0.046). Intra-graft variability was significantly lower with the rotating circular blade dermatome (F(1,118) = 26.75, p < 0.001). No significant differences were observed by operator experience or donor site. The rotating circular blade dermatome demonstrated superior depth accuracy and reduced intra-graft variability compared with traditional dermatome. These findings suggest that device design may mitigate operator-dependent variability and improve reproducibility in split-thickness skin graft harvesting.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Texas Tech University Health Sciences Center, School of Medicine, Lubbock, TX, USA.
- University Medical Center, Lubbock, TX, USA.
- University of Arkansas for Medical Sciences, College of Medicine, Orthopaedic Surgery, Little Rock, AK, USA.
- Kurtz Consulting Inc, Vernon Hills, IL, USA.
ORCID-Profile: Timothy Worley, Alexandra McDowell, Michelle Tarbox, John Griswold, Alan Pang, Debra Kurtz
Zitieren
APA
Worley, T., McDowell, A., Tarbox, M., Brown, E., Griswold, J., Pang, A., & Kurtz, D. (2026). Skin Graft Thickness Consistency: A Comparison of Traditional Dermatome and Rotating Circular Blade Technology. Journal of Burn Care & Research. https://doi.org/10.1093/jbcr/irag184
Vancouver
Worley T, McDowell A, Tarbox M, Brown E, Griswold J, Pang A, et al. Skin Graft Thickness Consistency: A Comparison of Traditional Dermatome and Rotating Circular Blade Technology. Journal of Burn Care & Research. 2026. doi:10.1093/jbcr/irag184
BibTeX
@article{Worley2026,
author = {Worley, Timothy and McDowell, Alexandra and Tarbox, Michelle and Brown, Elizabeth and Griswold, John and Pang, Alan and Kurtz, Debra},
title = {Skin Graft Thickness Consistency: A Comparison of Traditional Dermatome and Rotating Circular Blade Technology},
journal = {Journal of Burn Care & Research},
year = {2026},
doi = {10.1093/jbcr/irag184}
}
EUVIMED