EUVIMEDEUVIMED entdecken
Crossref

Home Oxygen Safety in an Urban Population: A Multipronged Approach

Wanda Horn, Janice Korenblatt, Elizabeth A Duthie, Lauren Huber, Iby Thomas, Daniel G Fein, Amy R Ehrlich

Journal of Burn Care & Research · 2025

DOI: 10.1093/jbcr/iraf076 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Burn Care & Research, 2025. Verfasst von Wanda Horn und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Geriatrics, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, United States. Hauptthemen laut MEDLINE: Burns, Oxygen Inhalation Therapy, Home Care Services, Urban Population. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Home oxygen improves the survival of patients with severe chronic hypoxic lung disease, but is associated with an increased risk of burns, fires, and fatalities. There is minimal data about potential risk factors for fires and burns in an urban population discharged from the hospital to the community on oxygen. This is a 7-year retrospective chart review of patients discharged on oxygen to a Certified Home Health Agency. The highest risk patients were defined as those believed by a nurse to be at imminent danger of causing a burn or fire and requiring review by an Emergency Committee; these are analyzed in more detail. A total of 1,301 patients were discharged on home oxygen. Twenty-six patients were identified as highest risk and required emergency interventions. Risk factors for burns and fires included: 85% active smokers, 46% substance use disorder, and 19% unstable psychiatric disease or an unreliable caregiver. The primary care physician in the community was unaware that the patient had oxygen in the home in 35% of these cases. A Home Oxygen Safety Committee was convened to address improvements in the Electronic Health Record, hospital infrastructure, and patient and caregiver education to improve home oxygen safety. Burns and fires related to home oxygen are rare events but can be devastating to the patient, caregivers, and community. Establishing a regulatory requirement that oxygen be included on the medication list at hospital discharge, and in the ambulatory setting, has the potential to improve transitions of care for this vulnerable population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BurnsOxygen Inhalation TherapyHome Care ServicesUrban PopulationFiresPatient SafetyHumansRetrospective StudiesMaleFemaleMiddle AgedAdultAgedRisk Factors

Stichwörter der Autor:innen

burnscigarettesfireshome oxygen

Autor:innen und Institutionen

  • Division of Geriatrics, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, United States.
  • Montefiore Home Care, Montefiore Medical Center, Bronx, NY, United States.
  • Patient Safety, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, United States.
  • Department of Family and Social Medicine, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, United States.
  • Division of Pulmonary Medicine, Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, United States.

Zitieren

APA

Horn, W., Korenblatt, J., Duthie, E. A., Huber, L., Thomas, I., Fein, D. G., & Ehrlich, A. R. (2025). Home Oxygen Safety in an Urban Population: A Multipronged Approach. Journal of Burn Care & Research. https://doi.org/10.1093/jbcr/iraf076

Vancouver

Horn W, Korenblatt J, Duthie EA, Huber L, Thomas I, Fein DG, et al. Home Oxygen Safety in an Urban Population: A Multipronged Approach. Journal of Burn Care & Research. 2025. doi:10.1093/jbcr/iraf076

BibTeX
@article{Horn2025,
  author = {Horn, Wanda and Korenblatt, Janice and Duthie, Elizabeth A and Huber, Lauren and Thomas, Iby and Fein, Daniel G and Ehrlich, Amy R},
  title = {Home Oxygen Safety in an Urban Population: A Multipronged Approach},
  journal = {Journal of Burn Care & Research},
  year = {2025},
  doi = {10.1093/jbcr/iraf076}
}
Kostenlos starten →