EUVIMEDEUVIMED entdecken
Crossref

A highly sensitive headspace gas chromatographic method fully optimized for fast routine determination of carboxyhemoglobin in postmortem blood

Roman Papoušek iD, Vladimíra Gebauerová, Marie Staňková, Petr Handlos iD, Edita Červenková, Denisa Ptáčková, Lucie Borovcová iD

Journal of Analytical Toxicology · 2025

DOI: 10.1093/jat/bkaf089 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Analytical Toxicology, 2025. Verfasst von Roman Papoušek und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Forensic Medicine, University Hospital Ostrava, Ostrava, 708 52, Czech Republic. Hauptthemen laut MEDLINE: Carboxyhemoglobin, Forensic Toxicology. Die Arbeit nennt 27 Literaturangaben. Gefördert von: Ministry of Health, Czech Republic-conceptual development of research organization (FNOs/2020), Ministry of Health, Czech Republic—conceptual development of research organization.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In some cases, the determination of carboxyhemoglobin (COHb) concentration in postmortem blood using standard spectrophotometric methods, may be either impossible or yield misleading results. In forensic laboratories, there is an increasing need to analyze COHb saturation in autopsy blood samples, the quality of which is often compromised by various factors. Therefore, a gas chromatographic method has been developed and validated to confirm the results of an established spectrophotometric method and to determine the concentration of COHb in postmortem samples affected by processes such as putrefaction or thermocoagulation. This method is based on automated headspace analysis of a blood sample treated with a solution of potassium hexacyanoferrate and saponin. It employs a combination of two capillary columns for chromatographic separation, followed by a highly sensitive detection system that incorporates a methanizer to convert carbon monoxide (CO) to methane couple to a flame ionization detector. The percentage of COHb concentration is calculated using the ratio of the analyzed blood to that of fully CO-saturated blood. Careful optimization of the method has reduced the sample requirement to 100 mg while maintaining high sensitivity. Additionally, the sample pretreatment process has been simplified to ensure that the method can be easily integrated into the routine operation of a conventional forensic laboratory. The method demonstrates linearity across a concentration range of 0.1% to 100% COHb. The determined values of limit of detection (<0.01% COHb) and limit of quantification (0.1% COHb) reflect excellent sensitivity. Overall, the validation study confirmed the method for its intended purpose. The method is particularly effective in reliably determining COHb content in putrefied and similarly degraded samples. Its robustness has been further validated through the analysis of dozens of real samples over more than 4 years.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CarboxyhemoglobinForensic ToxicologyHumansChromatography, GasReproducibility of ResultsLimit of DetectionFlame IonizationAutopsy

Substanzen

Carboxyhemoglobin

Autor:innen und Institutionen

  • Institute of Forensic Medicine, University Hospital Ostrava, Ostrava, 708 52, Czech Republic.
  • Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Pardubice, 532 10, Czech Republic.
  • Department of Forensic Medicine, Faculty of Medicine, University of Ostrava, Ostrava, 701 03, Czech Republic.
  • Department of Analytical Chemistry, Faculty of Science, Palacky University, Olomouc, 771 46, Czech Republic.

ORCID-Profile: Roman Papoušek, Petr Handlos, Lucie Borovcová

Förderung

  • Ministry of Health, Czech Republic-conceptual development of research organization (FNOs/2020)
  • Ministry of Health, Czech Republic—conceptual development of research organization

Zitieren

APA

Papoušek, R., Gebauerová, V., Staňková, M., Handlos, P., Červenková, E., Ptáčková, D., & Borovcová, L. (2025). A highly sensitive headspace gas chromatographic method fully optimized for fast routine determination of carboxyhemoglobin in postmortem blood. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/bkaf089

Vancouver

Papoušek R, Gebauerová V, Staňková M, Handlos P, Červenková E, Ptáčková D, et al. A highly sensitive headspace gas chromatographic method fully optimized for fast routine determination of carboxyhemoglobin in postmortem blood. Journal of Analytical Toxicology. 2025. doi:10.1093/jat/bkaf089

BibTeX
@article{Papouek2025,
  author = {Papoušek, Roman and Gebauerová, Vladimíra and Staňková, Marie and Handlos, Petr and Červenková, Edita and Ptáčková, Denisa and Borovcová, Lucie},
  title = {A highly sensitive headspace gas chromatographic method fully optimized for fast routine determination of carboxyhemoglobin in postmortem blood},
  journal = {Journal of Analytical Toxicology},
  year = {2025},
  doi = {10.1093/jat/bkaf089}
}
Kostenlos starten →