Immunalysis tapentadol assay reformulation resolves tramadol interference
Journal of Analytical Toxicology · 2025
DOI: 10.1093/jat/bkaf060 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Analytical Toxicology, 2025. Verfasst von Adeolu O Adegoke und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, University of Utah Health, Salt Lake City, UT 84132, United States. Hauptthemen laut MEDLINE: Tapentadol, Tramadol, Analgesics, Opioid, Substance Abuse Detection. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ARUP Institute for Clinical and Experimental Pathology.
Abstract (Originalsprache)
This study evaluated the performance of the Immunalysis Tapentadol 343 Urine Enzyme Immunoassay (EIA) screening kit, focusing on the prevalence of false-positive results due to cross-reactivity with tramadol. Tapentadol is a dual-action analgesic, modulating μ-opioid receptors and inhibiting norepinephrine reuptake, while tramadol, a structurally related compound, is a weak μ-opioid receptor agonist and norepinephrine/serotonin reuptake inhibitor. Cross-reactivity between these compounds can complicate urine drug screening results for adherence monitoring in chronic pain management. A total of 28 samples initially produced false-positive results for tapentadol BNl using the Immunalysis Tapentadol 343 Urine EIA screening kit. Liquid chromatography–tandem mass spectrometry (LC–MS/MS) was used to confirm the absence of tapentadol. Of the false-positive samples, 61% contained tramadol at concentrations below the manufacturer-reported cross-reactivity threshold of 60 000 ng/mL, indicating assay limitations in specificity. To address this issue, a newly reformulated Immunalysis Tapentadol 343UR Urine HEIA kit was evaluated for tramadol cross-reactivity. Upon retesting the 28 false-positive samples with the reformulated kit, no false positives were detected, with results consistent with LC–MS/MS confirmation. The rate of false-positive tapentadol screens in urine has substantially reduced since the implementation of the new tapentadol kit in routine testing. These findings demonstrate the importance of assay verification to assess cross-reactivity, particularly for structurally related compounds. The reformulated Immunalysis Tapentadol 343UR kit shows improved specificity, reducing false-positive rates and enhancing the accuracy of tapentadol detection in clinical and forensic toxicology applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Pathology, University of Utah Health, Salt Lake City, UT 84132, United States.
- ARUP Laboratories, Salt Lake City, UT 84108, United States.
- ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 84108, United States.
ORCID-Profile: Jessica M Boyd, Kamisha L Johnson-Davis
Förderung
- ARUP Institute for Clinical and Experimental Pathology
Zitieren
APA
Adegoke, A. O., Jackson, A. N., La'ulu, S. L., Anderson, C., Rudolf, J. W., Boyd, J. M., & Johnson-Davis, K. L. (2025). Immunalysis tapentadol assay reformulation resolves tramadol interference. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/bkaf060
Vancouver
Adegoke AO, Jackson AN, La'ulu SL, Anderson C, Rudolf JW, Boyd JM, et al. Immunalysis tapentadol assay reformulation resolves tramadol interference. Journal of Analytical Toxicology. 2025. doi:10.1093/jat/bkaf060
BibTeX
@article{Adegoke2025,
author = {Adegoke, Adeolu O and Jackson, Alexandria N and La'ulu, Sonia L and Anderson, Chelsie and Rudolf, Joseph W and Boyd, Jessica M and Johnson-Davis, Kamisha L},
title = {Immunalysis tapentadol assay reformulation resolves tramadol interference},
journal = {Journal of Analytical Toxicology},
year = {2025},
doi = {10.1093/jat/bkaf060}
}
EUVIMED