EUVIMEDEUVIMED entdecken
Open Access

A new automated method for the analysis of cotinine and trans-3′-hydroxycotinine in serum by LC–MS/MS

Danielle L Hopkins iD, Madeline L Weaver iD, Connie Sosnoff, Rayaj Ahamed iD, Lanqing Wang iD, Tiffany H Seyler iD

Journal of Analytical Toxicology · 01.11.2025 · 49 (9) · 664-672

DOI: 10.1093/jat/bkaf059 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Analytical Toxicology, online erschienen am 04.07.2025. Verfasst von Danielle L Hopkins und 5 weiteren Autor:innen. Beteiligte Einrichtung: Centers for Disease Control and Prevention, 4770 Buford Hwy, Atlanta, GA 30341, United States. Hauptthemen laut MEDLINE: Cotinine. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Intramural CDC HHS, CDC HHS, HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tobacco cigarette smoking is the leading cause of preventable diseases and death in the USA. Exposure to secondhand smoke (SHS) can also cause heart disease, lung cancer, and respiratory illness. Cotinine (COT) and trans-3′-hydroxycotinine (HCT) are the primary metabolites of nicotine, the main addictive alkaloid in tobacco products. For many years, we have measured serum levels of COT and HCT in National Health and Nutritional Examination Survey (NHANES) participants to monitor exposure of the US population to active smoking and SHS. As exposure to SHS is decreasing, a more sensitive analytical method is needed to detect the lower levels of these biomarkers for SHS assessment. We developed and validated a new automated method for the detection of COT and HCT in human serum. We implemented a new liquid handling automation system to aliquot and prepare samples using supported liquid extraction. Samples were analyzed by liquid chromatography–tandem mass spectrometry. The new automated sample preparation method increases sample throughput by reducing sample cleanup time to 2 hours for preparing a 96-well plate. The method has excellent sensitivity, specificity, precision (<10%), and accuracy (±15%). We were able to lower the estimated limit of detection (LOD) for COT by 33% and HCT by 73% from our previous LOD. The new LODs for COT and HCT are 0.010 and 0.004 ng/mL, respectively. These lower LODs would enable better detection of SHS in future NHANES surveys.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CotinineHumansTandem Mass SpectrometryChromatography, LiquidTobacco Smoke PollutionLimit of DetectionAutomationBiomarkersReproducibility of ResultsLiquid Chromatography-Mass Spectrometry

Substanzen

CotininehydroxycotinineTobacco Smoke PollutionBiomarkers

Autor:innen und Institutionen

  • Centers for Disease Control and Prevention, 4770 Buford Hwy, Atlanta, GA 30341, United States.
  • Oak Ridge Institute for Science and Education, Oak Ridge, TN 37830, United States.

ORCID-Profile: Danielle L Hopkins, Madeline L Weaver, Rayaj Ahamed, Lanqing Wang, Tiffany H Seyler

Förderung

  • Intramural CDC HHS
  • CDC HHS
  • HHS
  • Centers for Disease Control and Prevention
  • Department of Health and Human Services

Zitieren

APA

Hopkins, D. L., Weaver, M. L., Sosnoff, C., Ahamed, R., Wang, L., & Seyler, T. H. (2025). A new automated method for the analysis of cotinine and trans-3′-hydroxycotinine in serum by LC–MS/MS. Journal of Analytical Toxicology, 49(9), 664-672. https://doi.org/10.1093/jat/bkaf059

Vancouver

Hopkins DL, Weaver ML, Sosnoff C, Ahamed R, Wang L, Seyler TH. A new automated method for the analysis of cotinine and trans-3′-hydroxycotinine in serum by LC–MS/MS. Journal of Analytical Toxicology. 2025;49(9):664-672. doi:10.1093/jat/bkaf059

BibTeX
@article{Hopkins2025,
  author = {Hopkins, Danielle L and Weaver, Madeline L and Sosnoff, Connie and Ahamed, Rayaj and Wang, Lanqing and Seyler, Tiffany H},
  title = {A new automated method for the analysis of cotinine and trans-3′-hydroxycotinine in serum by LC–MS/MS},
  journal = {Journal of Analytical Toxicology},
  year = {2025},
  volume = {49},
  number = {9},
  pages = {664--672},
  doi = {10.1093/jat/bkaf059}
}
Kostenlos starten →