EUVIMEDEUVIMED entdecken
Crossref

Increase of PEth after Single Consumption of Alcohol and Evaluation of a Volumetric DBS Filter Paper Device

Frederike Stöth iD, Kevin Koch iD, Matthias Bantle iD, Philipp Pütz iD, Felix Wortmann iD, Wolfgang Weinmann iD

Journal of Analytical Toxicology · 2023

DOI: 10.1093/jat/bkad009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Analytical Toxicology, 2023. Verfasst von Frederike Stöth und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Forensic Medicine, Forensic Toxicology and Chemistry, University of Bern, Murtenstrasse 26, 3008 Bern, Switzerland. Hauptthemen laut MEDLINE: Ethanol, Dried Blood Spot Testing. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Direct alcohol biomarkers are of growing interest for the assessment of alcohol consumption, with particular interest in phosphatidylethanol (PEth) in recent years. PEth is only formed when alcohol is present in the body. However, there is no statement about how much the PEth concentration increases after single moderate alcohol consumption. This study was conducted to determine the increase in PEth concentrations after a single drinking event. Additionally, a new volumetric sampling device (volumetric dried blood spot cards (DBSV)) was evaluated, which was designed to simplify further sampling processes and to allow for easy self-sampling. Dried blood samples from 31 volunteers were collected before and after single alcohol consumption with a mean maximum breath alcohol concentration of 0.4 mg/L (range: 0.30–0.55 mg/L). PEth concentrations were determined after automated extraction by liquid chromatography--tandem mass spectrometry. PEth 16:0/18:1 and PEth 16:0/18:2 concentrations increased to an average of 45 ng/mL each in patients starting below 20 ng/mL (range: 25.0–57.0 ng/mL for PEth 16:0/18:1; range 26.8–62.3 ng/mL for PEth 16:0/18:2). PEth concentrations in patients starting above 20 ng/mL increased by a mean of 30 ng/mL (range: 6.2–71.3 ng/mL for PEth 16:0/18:1; range 8.8–65.3 ng/mL for PEth 16:0/18:2). In addition, the comparison of the new sampling device DBSV with a standard filter paper card (with volumetrically applied 20 µL of blood samples) yielded a close agreement for the determined PEth concentrations in 24 forensic samples and three external controls. Therefore, the sampling device DBSV proved to be suitable for the determination of PEth concentrations in blood.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EthanolDried Blood Spot TestingHumansChromatography, LiquidMass SpectrometryBiomarkersAlcohol Drinking

Substanzen

EthanolBiomarkers

Autor:innen und Institutionen

  • Institute of Forensic Medicine, Forensic Toxicology and Chemistry, University of Bern, Murtenstrasse 26, 3008 Bern, Switzerland.
  • Institute of Technology Management, University of St. Gallen, Dufourstrasse 40a, 9000 St. Gallen, Switzerland.
  • Institute of Forensic Medicine, Medical Center, University of Freiburg, Albertstraße 9, 79104 Freiburg, Germany.

ORCID-Profile: Frederike Stöth, Kevin Koch, Matthias Bantle, Philipp Pütz, Felix Wortmann, Wolfgang Weinmann

Zitieren

APA

Stöth, F., Koch, K., Bantle, M., Pütz, P., Wortmann, F., & Weinmann, W. (2023). Increase of PEth after Single Consumption of Alcohol and Evaluation of a Volumetric DBS Filter Paper Device. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/bkad009

Vancouver

Stöth F, Koch K, Bantle M, Pütz P, Wortmann F, Weinmann W. Increase of PEth after Single Consumption of Alcohol and Evaluation of a Volumetric DBS Filter Paper Device. Journal of Analytical Toxicology. 2023. doi:10.1093/jat/bkad009

BibTeX
@article{Stth2023,
  author = {Stöth, Frederike and Koch, Kevin and Bantle, Matthias and Pütz, Philipp and Wortmann, Felix and Weinmann, Wolfgang},
  title = {Increase of PEth after Single Consumption of Alcohol and Evaluation of a Volumetric DBS Filter Paper Device},
  journal = {Journal of Analytical Toxicology},
  year = {2023},
  doi = {10.1093/jat/bkad009}
}
Kostenlos starten →