Collection Tubes Can Cause False Elevations in Occupational and Clinical Evaluation of Antimony Exposure
Journal of Analytical Toxicology · 2023
DOI: 10.1093/jat/bkac010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Analytical Toxicology, 2023. Verfasst von Yifei K Yang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, School of Medicine, University of Utah, 201 Presidents' Circle, Salt Lake City, UT 84112, USA. Hauptthemen laut MEDLINE: Antimony, Trace Elements. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
Occupational exposure to antimony has become rare in the past decades due to antimony mine closures and technological improvement in antimony processing plants in the USA. Although antimony’s ubiquitous presence in plasticwares does not pose known health risk, it can present as a potential contaminant to antimony analysis for occupational exposure assessment. To understand the level of antimony contamination from plastic collection devices, we evaluated two different whole-blood plastic collection tubes that are routinely used for trace and toxic element assessment: royal blue BD Vacutainer® EDTA tube and Greiner VACUETTE® trace elements sodium heparin tube. We analyzed how different fill volumes may impact the concentrations of antimony detected. Although both collection tubes can introduce antimony contaminations to nitric acid and neutral buffer rinse, the Greiner heparin tube introduces a significantly lower amount of antimony to freshly collected whole-blood samples compared to the BD EDTA tube. When patients’ samples are collected with BD EDTA tubes, they would exhibit elevated antimony concentrations that can be interpreted as potential antimony exposure. We conclude that the royal blue BD EDTA plastic tube is not suitable to evaluate blood antimony levels, and laboratories need to validate their own alternative sources when the glass tubes are not available.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Pathology, School of Medicine, University of Utah, 201 Presidents' Circle, Salt Lake City, UT 84112, USA.
- ARUP Laboratories, 500 Chipeta Way, Salt Lake City, UT 84108, USA.
ORCID-Profile: Yifei K Yang
Zitieren
APA
Yang, Y. K., Genesi, B., & Adams, A. H. (2023). Collection Tubes Can Cause False Elevations in Occupational and Clinical Evaluation of Antimony Exposure. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/bkac010
Vancouver
Yang YK, Genesi B, Adams AH. Collection Tubes Can Cause False Elevations in Occupational and Clinical Evaluation of Antimony Exposure. Journal of Analytical Toxicology. 2023. doi:10.1093/jat/bkac010
BibTeX
@article{Yang2023,
author = {Yang, Yifei K and Genesi, Bryce and Adams, Austin H},
title = {Collection Tubes Can Cause False Elevations in Occupational and Clinical Evaluation of Antimony Exposure},
journal = {Journal of Analytical Toxicology},
year = {2023},
doi = {10.1093/jat/bkac010}
}
EUVIMED