Full Validation of an HPLC-UV Analytical Method for Azithromycin Quantification Using Comparative Approaches: Total Error and ISO-GUM for Assessment of Uncertainty
Journal of AOAC International · 01.07.2025 · 108 (4) · 506-518
DOI: 10.1093/jaoacint/qsaf044 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of AOAC International, online erschienen am 25.04.2025. Verfasst von Wafaa El-Ghaly und 9 weiteren Autor:innen. Beteiligte Einrichtung: Mohammed VI University of Sciences and Health (UM6SS), Faculty of Pharmacy, Boulevard Mohammed Taïeb Naciri, Commune Hay Hassani, 82403, Casablanca, …. Hauptthemen laut MEDLINE: Azithromycin, Anti-Bacterial Agents. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
Background
Azithromycin is a complex molecule derived from erythromycin. The control of its dosage in conventional release tablets requires the analytical validation of its method to ensure accurate quantification and provide confidence in the reliability of the results for informed decision-making.
Objective
This study aims to validate an innovative method for azithromycin quantification using the accuracy profile. Additionally, a comparison is made between the uncertainty measurements calculated from the validation data using two formulas proposed by Feinberg et al. and Saffaj and Ihssane and contrasted with the ISO GUM approach.
Methods
A liquid chromatography system intended for azithromycin analysis equipped with a reversed-phase C18 stationary phase consisting of octadecyl silyl vinyl polymer in a UV detector operating at 210 nm at a temperature of 40°C in isocratic elution using a mobile phase of acetonitrile and dipotassium hydrogen phosphate buffer (6.7 g/L), in the fraction of (60:40, v/v) at pH = 8.
Results
The various accuracy profiles are illustrated to ensure that a known quantity of anticipated findings acquired through the method stand inside the tolerance interval of 95% and remain within the previously set acceptance limits of ±5%. Measurement uncertainty provides comparable values using both formulas of the total error approach. However, it was observed that the ISO-GUM approach tends to overestimate the expanded uncertainty. Specifically, while the ISO-GUM approach provides a rigorous framework, the use of the validation data offers a more empirical uncertainty estimation.
Conclusion
The approach based on the total error grants the ability to accurately close the routine uncertainty, emphasizing a complete validation. Highlights The proposed method is robust for pharmaceutical application, demonstrating good accuracy, with 95% of tolerance and uncertainty limits falling within the predefined acceptance limits of ±5%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Mohammed VI University of Sciences and Health (UM6SS), Faculty of Pharmacy, Boulevard Mohammed Taïeb Naciri, Commune Hay Hassani, 82403, Casablanca, Morocco.
- Mohammed VI University of Sciences and Health, Drug Sciences Laboratory, Faculty of Pharmacy, Boulevard Mohammed Taïeb Naciri, Commune Hay Hassani, 82403, Casablanca, Morocco.
- Sidi Mohamed Ben Abdallah University, Applied Organic Chemistry Laboratory, Faculty of Sciences and Technology (FST), Route d'Imouzzer, B.P. 2202, 30000 Fès, Morocco.
- Mohammed V University, Pharmacology and Toxicology Laboratory, Biostatistical, Clinical and Epidemiological Research Laboratory, Faculty of Medicine and Pharmacy, Avenue Mohammed Belarbi Alaoui, B.P. 6203, Rabat, 10100,…
- Hassan II Agronomic and Veterinary Institute, Department of Veterinary Biological Sciences and Pharmaceuticals, Madinat Al Irfane, Rabat, 10101, Morocco.
- Dioma Pharmaceutical Manufacturing Company, KM 24 Route de Rabat, Ould Moumen Beni Yakhlef, 28815 Mohammedia, Morocco.
ORCID-Profile: Wafaa El-Ghaly, Asmae Elouari, Lamia Zaari Lambarki, Samir Ahid, Taha El Kamli, Adnane Benmoussa, Fadil Bakkali, Nour-Iddin Bamou, Taoufiq Saffaj, Fayssal Jhilal
Zitieren
APA
El-Ghaly, W., Elouari, A., Zaari Lambarki, L., Ahid, S., El Kamli, T., Benmoussa, A., Bakkali, F., Bamou, N. I., Saffaj, T., & Jhilal, F. (2025). Full Validation of an HPLC-UV Analytical Method for Azithromycin Quantification Using Comparative Approaches: Total Error and ISO-GUM for Assessment of Uncertainty. Journal of AOAC International, 108(4), 506-518. https://doi.org/10.1093/jaoacint/qsaf044
Vancouver
El-Ghaly W, Elouari A, Zaari Lambarki L, Ahid S, El Kamli T, Benmoussa A, et al. Full Validation of an HPLC-UV Analytical Method for Azithromycin Quantification Using Comparative Approaches: Total Error and ISO-GUM for Assessment of Uncertainty. Journal of AOAC International. 2025;108(4):506-518. doi:10.1093/jaoacint/qsaf044
BibTeX
@article{ElGhaly2025,
author = {El-Ghaly, Wafaa and Elouari, Asmae and Zaari Lambarki, Lamia and Ahid, Samir and El Kamli, Taha and Benmoussa, Adnane and Bakkali, Fadil and Bamou, Nour-Iddin and Saffaj, Taoufiq and Jhilal, Fayssal},
title = {Full Validation of an HPLC-UV Analytical Method for Azithromycin Quantification Using Comparative Approaches: Total Error and ISO-GUM for Assessment of Uncertainty},
journal = {Journal of AOAC International},
year = {2025},
volume = {108},
number = {4},
pages = {506--518},