EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Purity Assessment of Honey Based on Compound Specific Stable Carbon Isotope Ratios Obtained by LC-IRMS

Franz Ulberth iD, Eric Aries, Oliver De Rudder, Georgios Kaklamanos, Alain Maquet iD

Journal of AOAC International · 01.10.2024 · 107 (5) · 884-887

DOI: 10.1093/jaoacint/qsae021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of AOAC International, online erschienen am 15.03.2024. Verfasst von Franz Ulberth und 4 weiteren Autor:innen. Beteiligte Einrichtung: European Commission, Joint Research Centre (JRC), 2440 Geel, Belgium. Hauptthemen laut MEDLINE: Honey, Carbon Isotopes, Mass Spectrometry. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The use of stable carbon isotope ratios (δ13C) of sugar fractions of honey is a powerful tool to detect adulteration with sugar syrups. This is accomplished by calculating differences of the δ13C values between individual honey saccharides and comparing them to published purity criteria. A liquid chromatography–isotope ratio mass spectrometry (LC-IRMS) method for the determination of δ13C values of sugars in honey was previously validated by an interlaboratory comparison, but no further guidance was given how to include the obtained precision figures of the compound-specific δ13C values in the purity assessment of honey.

Objective

To use existing data to estimate the standard deviation of the repeatability (sr) and reproducibility (sR) of differences (Δ δ13C) between the δ13C values of individual honey saccharides.

Methods

Previously published δ13C values were used to calculate differences (Δ δ13C values) between δ13C fructose—δ13C glucose, δ13C glucose—δ13C disaccharides, etc. in a honey sample; sr and sR of Δ δ13C values were calculated according to ISO 5725–2:2019.

Results

The Δ δ13C sr and sR values were essentially of the same magnitude as the sr and sR values of δ13C values of the sugar fractions. The precision of the Δ δ13C values was used to estimate the critical difference for comparing a test result with a reference value according to ISO 5725–6:1994. This varied between 0.26 and 1.10‰.

Conclusion

The estimated critical differences can be used to determine whether a honey test result complies with published Δ δ13C purity criteria. Highlight The proposed procedure will increase confidence in decisions based on compound-specific δ13C values regarding the conformity of honey with published purity criteria.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HoneyCarbon IsotopesMass SpectrometryChromatography, LiquidReproducibility of ResultsFood Contamination

Substanzen

Carbon Isotopes

Autor:innen und Institutionen

  • European Commission, Joint Research Centre (JRC), 2440 Geel, Belgium.

ORCID-Profile: Franz Ulberth, Alain Maquet

Zitieren

APA

Ulberth, F., Aries, E., De Rudder, O., Kaklamanos, G., & Maquet, A. (2024). Purity Assessment of Honey Based on Compound Specific Stable Carbon Isotope Ratios Obtained by LC-IRMS. Journal of AOAC International, 107(5), 884-887. https://doi.org/10.1093/jaoacint/qsae021

Vancouver

Ulberth F, Aries E, De Rudder O, Kaklamanos G, Maquet A. Purity Assessment of Honey Based on Compound Specific Stable Carbon Isotope Ratios Obtained by LC-IRMS. Journal of AOAC International. 2024;107(5):884-887. doi:10.1093/jaoacint/qsae021

BibTeX
@article{Ulberth2024,
  author = {Ulberth, Franz and Aries, Eric and De Rudder, Oliver and Kaklamanos, Georgios and Maquet, Alain},
  title = {Purity Assessment of Honey Based on Compound Specific Stable Carbon Isotope Ratios Obtained by LC-IRMS},
  journal = {Journal of AOAC International},
  year = {2024},
  volume = {107},
  number = {5},
  pages = {884--887},
  doi = {10.1093/jaoacint/qsae021}
}