External validation of the Epic sepsis predictive model in 2 county emergency departments
JAMIA Open · 08.10.2024 · 7 (4)
DOI: 10.1093/jamiaopen/ooae133 ↗Kurz gefasst
Fachartikel in der Zeitschrift JAMIA Open, online erschienen am 13.11.2024. Verfasst von Daniel G Ostermayer und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, McGovern Medical School, UT Health at the University of Texas Health Science Center at Houston, Houston, TX 77030, …. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Sepsis
Abstract (Originalsprache)
Objective
To describe the diagnostic characteristics of the proprietary Epic sepsis predictive model best practice advisory (BPA) alert for physicians in the emergency department (ED). Materials and Methods The Epic Sepsis Predictive Model v1.0 (ESPMv1), a proprietary algorithm, is intended to improve provider alerting of patients with a likelihood of developing sepsis. This retrospective cohort study conducted at 2 county EDs from January 1, 2023 to December 31, 2023 evaluated the predictive characteristics of the ESPMv1 for 145 885 encounters. Sepsis was defined according to the Sepsis-3 definition with the onset of sepsis defined as an increase in 2 points on the Sequential Organ Function Assessment (SOFA) score in patients with the ordering of at least one blood culture and antibiotic. Alerting occurred at an Epic recommended model threshold of 6.
Results
The ESPMv1 BPA alert was present in 7183 (4.9%) encounters of which 2253 had sepsis, and not present in 138 702 encounters of which 3180 had sepsis. Within a 6-hour time window for sepsis, the ESPMv1 had a sensitivity of 14.7%, specificity of 95.3%, positive predictive value of 7.6%, and negative predictive value of 97.7%. Providers were alerted with a median lead time of 0 minutes (80% CI, −6 hours and 42 minutes to 12 hours and 0 minutes).
Discussion
In our population, the ESPMv1 alerted providers with a median lead time of 0 minutes (80% CI, −6 hours and 42 minutes to 12 hours and 0 minutes) and only alerted providers in half of the cases prior to sepsis occurrence. This suggests that the ESPMv1 alert is adding little assistance to physicians identifying sepsis. With clinicians treating sepsis 50% of the time without an alert, pop-ups can only marginally assist in disease identification.
Conclusions
The ESPMv1 provides suboptimal diagnostic characteristics for undifferentiated patients in a county ED.
Autor:innen und Institutionen
- Department of Emergency Medicine, McGovern Medical School, UT Health at the University of Texas Health Science Center at Houston, Houston, TX 77030, United States.
- Department of Health Informatics and Data Science, Harris Health System, Houston, TX 77401, United States.
- Department of Surgery, Baylor College of Medicine, Houston, TX 77030, United States.
- Department of Emergency Medicine, Baylor College of Medicine, Houston, TX 77030, United States.
Zitieren
APA
Ostermayer, D. G., Braunheim, B., Mehta, A. M., Ward, J., Andrabi, S., & Sirajuddin, A. M. (2024). External validation of the Epic sepsis predictive model in 2 county emergency departments. JAMIA Open, 7(4). https://doi.org/10.1093/jamiaopen/ooae133
Vancouver
Ostermayer DG, Braunheim B, Mehta AM, Ward J, Andrabi S, Sirajuddin AM. External validation of the Epic sepsis predictive model in 2 county emergency departments. JAMIA Open. 2024;7(4). doi:10.1093/jamiaopen/ooae133
BibTeX
@article{Ostermayer2024,
author = {Ostermayer, Daniel G and Braunheim, Benjamin and Mehta, Amit M and Ward, Jeremy and Andrabi, Sara and Sirajuddin, Anwar Mohammad},
title = {External validation of the Epic sepsis predictive model in 2 county emergency departments},
journal = {JAMIA Open},
year = {2024},
volume = {7},
number = {4},
doi = {10.1093/jamiaopen/ooae133}
}