Comparison of clinical outcomes of sepsis patients in two county emergency departments using systemic inflammatory response syndrome versus Epic’s proprietary severe sepsis alert
Journal of the American Medical Informatics Association · 2026
DOI: 10.1093/jamia/ocaf207 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of the American Medical Informatics Association, 2026. Verfasst von Daniel G Ostermayer und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, McGovern Medical School, UT Health at the University of Texas Health Science Center at Houston, Houston, TX 77030, …. Hauptthemen laut MEDLINE: Emergency Service, Hospital, Sepsis, Systemic Inflammatory Response Syndrome, Decision Support Systems, Clinical. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Themen: Sepsis
Abstract (Originalsprache)
Objectives
To compare the clinical outcomes of sepsis patients when an augmented systemic inflammatory response syndrome (SIRS+) and the Epic sepsis predictive model version 1 (ESPMv1) alert were active in the emergency department at two county hospitals. Materials and Methods This retrospective study from January 2018 to January 2024, evaluated the clinical outcomes of 881 201 emergency department patients of which 29 852 patients were septic. From January 2018 to June 2022 sepsis notices were presented to physicians based on a SIRS plus organ dysfunction criteria and from December 2022 to January 2024 using the ESPMv1 alert. Sepsis was defined according to the Sepsis-3 definition with the onset of sepsis defined as two or more points on the Sequential Organ Function Assessment (SOFA) score in patients where physicians ordered at least one blood culture and antibiotic. SIRS+ alerting occurred when 2 of 4 criteria was reached plus one organ dysfunction measurement. The ESPMv1 alerting occurred at the Epic recommended threshold of six. We evaluated the times to blood cultures, antibiotics and ICU admission requests, and in-hospital death rates.
Results
SIRS+ alerts had a sensitivity of 14.25%, specificity 96.1%, positive predicative value (PPV) of 7.8% and negative predative value (NPV) of 98%. The ESPMv1 had a sensitivity of 15.6%, specificity 95.4%, positive predictive value of 8.1%, and negative predictive value of 98% for diagnosing sepsis. No statistical differences in time to antibiotics (5.1 vs 5.9 h), time to blood culture draws (3.6 vs 3.5 h) or time to ICU admission (10.4 vs 9.6 h) were observed. We did observe a difference in hospital death rates between the two time periods (11% vs 8%) but no statistical difference when adjusting for unvaccinated covid-19 (OR 0.95 [0.87-1.03]). Discussion and Conclusion No statistically significant clinical differences or performance metrics were observed between SIRS+ based alerting and ESPMv1 alerts in an undifferentiated emergency department population. Both alerting systems had similarly poor diagnostic characteristics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Emergency Medicine, McGovern Medical School, UT Health at the University of Texas Health Science Center at Houston, Houston, TX 77030, United States.
- Department of Health Informatics and Data Science, Harris Health System, Bellaire, TX 77401, United States.
- Department of Trauma and Acute Care Surgery, Baylor College of Medicine, Houston, TX 77030, United States.
- Department of Emergency Medicine, Baylor College of Medicine, Houston, TX 77030, United States.
Zitieren
APA
Ostermayer, D. G., Braunheim, B., Mehta, A., Ward, J., Andrabi, S., & Sirajuddin, A. M. (2026). Comparison of clinical outcomes of sepsis patients in two county emergency departments using systemic inflammatory response syndrome versus Epic’s proprietary severe sepsis alert. Journal of the American Medical Informatics Association. https://doi.org/10.1093/jamia/ocaf207
Vancouver
Ostermayer DG, Braunheim B, Mehta A, Ward J, Andrabi S, Sirajuddin AM. Comparison of clinical outcomes of sepsis patients in two county emergency departments using systemic inflammatory response syndrome versus Epic’s proprietary severe sepsis alert. Journal of the American Medical Informatics Association. 2026. doi:10.1093/jamia/ocaf207
BibTeX
@article{Ostermayer2026,
author = {Ostermayer, Daniel G and Braunheim, Benjamin and Mehta, Amit and Ward, Jeremy and Andrabi, Sara and Sirajuddin, Anwar Mohammad},
title = {Comparison of clinical outcomes of sepsis patients in two county emergency departments using systemic inflammatory response syndrome versus Epic’s proprietary severe sepsis alert},
journal = {Journal of the American Medical Informatics Association},
year = {2026},
doi = {10.1093/jamia/ocaf207}
}
EUVIMED