EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

An Update on State-of-the-Art Performance for Precision in Medical Laboratories

Jeremie M Gras, Delphine A Collin-Chavagnac, Florian Scherrer, Jean-Baptiste Raimbourg, Cyrille Biette, Michel Vaubourdolle, Anne J Vassault

The Journal of Applied Laboratory Medicine · 04.11.2026 · 11 (6) · 1512-1535

DOI: 10.1093/jalm/jfag125 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Applied Laboratory Medicine, online erschienen am 28.08.2026. Verfasst von Jeremie M Gras und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institut de Pathologie et de Génétique, Gosselies, Belgium. Hauptthemen laut MEDLINE: Laboratories, Clinical, Clinical Laboratory Techniques. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has established a three-stage model of criteria to set analytical performance specifications (APS). The third model is based on state-of-the-art (SoA), which has been described as the highest level of analytical performance with currently available methods. However, an up-to-date, comprehensive, easily usable SoA database does not currently exist.

Methods

Data mining was performed using a data management package (Unity Real Time) for Internal quality control (IQC) and interlaboratory comparisons (ILC). For each analyte, the coefficient of variation (CV) values reported by the 50th, 90th, and 95th percentiles of laboratories were extracted and then the median intralaboratory CV50, CV90, and CV95 values were calculated.

Results

Using >775 million quality control (QC) measurements, an updated SoA database includes >100 analytes commonly performed in the fields of clinical biochemistry, hematology, hemostasis, therapeutic drug monitoring (TDM), and serology. The number of QC measurements of each analysis, for 3 specific levels of concentration, ranged from 1090 to 9 163 824 to evaluate the impact of concentration level on the method precision for each analysis.

Conclusions

This study provides an updated SoA database for precision that is of particular importance in circumstances where EFLM Biological Variation Database-derived APS do not exist, cannot be generated with current methods, or are inappropriate for pathophysiologic states. The impact of concentration level on precision data is also reported.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Laboratories, ClinicalClinical Laboratory TechniquesQuality ControlHumansData MiningDatabases, FactualReproducibility of Results

Autor:innen und Institutionen

  • Institut de Pathologie et de Génétique, Gosselies, Belgium.
  • Hospices Civils de Lyon, Centre Hospitalier Lyon-Sud, Pierre-Benite, France.
  • Laboratoire de Biologie Médicale Barla, Groupe Innovie, Nice, France.
  • Bio-Rad Laboratories, Marnes-La-Coquette, France.
  • Siemens Healthineers, Courbevoie, France.
  • AP-HP Sorbonne University, Paris, France.

Zitieren

APA

Gras, J. M., Collin-Chavagnac, D. A., Scherrer, F., Raimbourg, J. B., Biette, C., Vaubourdolle, M., & Vassault, A. J. (2026). An Update on State-of-the-Art Performance for Precision in Medical Laboratories. The Journal of Applied Laboratory Medicine, 11(6), 1512-1535. https://doi.org/10.1093/jalm/jfag125

Vancouver

Gras JM, Collin-Chavagnac DA, Scherrer F, Raimbourg JB, Biette C, Vaubourdolle M, et al. An Update on State-of-the-Art Performance for Precision in Medical Laboratories. The Journal of Applied Laboratory Medicine. 2026;11(6):1512-1535. doi:10.1093/jalm/jfag125

BibTeX
@article{Gras2026,
  author = {Gras, Jeremie M and Collin-Chavagnac, Delphine A and Scherrer, Florian and Raimbourg, Jean-Baptiste and Biette, Cyrille and Vaubourdolle, Michel and Vassault, Anne J},
  title = {An Update on State-of-the-Art Performance for Precision in Medical Laboratories},
  journal = {The Journal of Applied Laboratory Medicine},
  year = {2026},
  volume = {11},
  number = {6},
  pages = {1512--1535},
  doi = {10.1093/jalm/jfag125}
}
Kostenlos starten →