EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accessible Prostate-Specific Antigen Testing through Finger-Stick Dried Blood Spots and Routine Laboratory Analyzers

Elizabeth M van Vugt, Lotte Hofstee, Leosa R Soels, Michael Y Schakelaar, Wouter M Tiel Groenestege iD

The Journal of Applied Laboratory Medicine · 03.08.2026

DOI: 10.1093/jalm/jfag119 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Applied Laboratory Medicine, online erschienen am 03.08.2026. Verfasst von Elizabeth M van Vugt und 4 weiteren Autor:innen. Beteiligte Einrichtung: Central Diagnostic Laboratory, University Medical Center Utrecht, University of Utrecht, Utrecht, the Netherlands. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens Healthineers.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Prostate-specific antigen (PSA) is a biomarker used for detection, screening, and follow-up of prostate cancer. Traditional PSA quantification requires venipuncture, which poses challenges in collection, storage, and transportation. Dried blood spot (DBS) technology presents a promising alternative for measuring PSA levels, potentially facilitating telemedicine, and large-scale screening programs.

Methods

PSA concentrations were measured in paired capillary finger-stick DBS and venous serum samples from 75 patients using a Siemens immunochemistry analyzer. For DBS samples, PSA was extracted using PBS prior to analysis. Additional validation of stability, hematocrit effects, precision, and limits of blank and quantitation was performed according to corresponding Clinical and Laboratory Standards Institute standards.

Results

The DBS PSA assay demonstrated good analytical performance, with total CVs of 4.5% and 6.1% at PSA concentrations of 11.5 µg/L and 3.8 µg/L, respectively. Limit of blank, limit of detection, and limit of quantitation were 0.24 µg/L, 0.28 µg/L, and 0.70 µg/L, respectively. Method comparison showed strong agreement between venous serum and finger-stick DBS (R2 = 0.987) with minimal bias. Stability studies showed that PSA remained stable for up to 31 days between −20°C and +30°C. Hematocrit affected measured PSA concentrations, but results remained within predefined total allowable error limits across 0.25–0.50 L/L. Variations in double spotting, blood volume, and number of spots did not affect PSA concentrations with a consistent trend.

Conclusions

PSA can be accurately measured from finger-stick DBS on an automated high-throughput immunochemistry analyzer. This method is less invasive for patients and may facilitate at-home self-sampling supporting (tele)diagnostics, screening, and follow-up.

Autor:innen und Institutionen

  • Central Diagnostic Laboratory, University Medical Center Utrecht, University of Utrecht, Utrecht, the Netherlands.
  • Department of Pathology, University Medical Center Utrecht, University of Utrecht, Utrecht, the Netherlands.

ORCID-Profile: Wouter M Tiel Groenestege

Förderung

  • Siemens Healthineers

Zitieren

APA

van Vugt, E. M., Hofstee, L., Soels, L. R., Schakelaar, M. Y., & Tiel Groenestege, W. M. (2026). Accessible Prostate-Specific Antigen Testing through Finger-Stick Dried Blood Spots and Routine Laboratory Analyzers. The Journal of Applied Laboratory Medicine. https://doi.org/10.1093/jalm/jfag119

Vancouver

van Vugt EM, Hofstee L, Soels LR, Schakelaar MY, Tiel Groenestege WM. Accessible Prostate-Specific Antigen Testing through Finger-Stick Dried Blood Spots and Routine Laboratory Analyzers. The Journal of Applied Laboratory Medicine. 2026. doi:10.1093/jalm/jfag119

BibTeX
@article{vanVugt2026,
  author = {van Vugt, Elizabeth M and Hofstee, Lotte and Soels, Leosa R and Schakelaar, Michael Y and Tiel Groenestege, Wouter M},
  title = {Accessible Prostate-Specific Antigen Testing through Finger-Stick Dried Blood Spots and Routine Laboratory Analyzers},
  journal = {The Journal of Applied Laboratory Medicine},
  year = {2026},
  doi = {10.1093/jalm/jfag119}
}
Kostenlos starten →