Result Interpretation in Skewed Populations—Are Common Reference Intervals Inadequate?
The Journal of Applied Laboratory Medicine · 04.11.2026 · 11 (6) · 1325-1336
DOI: 10.1093/jalm/jfag083 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Applied Laboratory Medicine, online erschienen am 09.06.2026. Verfasst von Dennis J Orton und 2 weiteren Autor:innen. Beteiligte Einrichtung: BC Women's and Children's Hospital and Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, BC, Canada. Hauptthemen laut MEDLINE: Testosterone, Sodium. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Reference intervals (RIs) are defined as the central 95th percentile of a healthy population, and many biomarkers exhibit a skewed result distribution. Here we demonstrate interpretive variations for results from a gaussian vs skewed distribution RI.
Methods
De-identified patient data were extracted from the laboratory information system for sodium and total testosterone, representing approximately gaussian and skewed reference populations, respectively. RIs and the Box–Cox variables (lambda, mu, and sigma) were obtained using refineR, with individual results and population distributions evaluated using RI midpoint vs median, interquartile range (IQR) values, z scores, abnormality flagging rates, and cumulative percentiles.
Results
For sodium, the RI midpoint, population mean, and median were similar at 138.8 and 139.0 mEq/L, respectively. Total testosterone demonstrated a skewed result distribution with RI midpoint (473 ng/dL; 16.3 nmol/L) closer to the 75th percentile (522 ng/dL; 18.1 nmol/L), impacting interpretation when results fall in the lower half of the RI. By illustration, a testosterone result of 294 ng/dL (10.2 nmol/L) was misinterpreted as “borderline low.” Reporting the z score of −0.55 and cumulative percentile of 0.28 may have provided assurance this result is well within a “disease-free” population range, preventing unnecessary investigation. Conversely, for a case of serial sodium results of 143 to 146 mEq/L in a polydipsic patient, presentation of z scores (1.97 to 3.01) and cumulative percentiles 0.97 to 1.00 may have prompted further investigation, preventing delayed disease recognition.
Conclusions
RIs help interpret laboratory results vs a “disease-free” population; however, skewed distributions may affect result interpretation when clinicians lack knowledge of population result distributions. Interpretive aids may improve comprehension.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- BC Women's and Children's Hospital and Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, BC, Canada.
- Alberta Precision Laboratories and Department of Pathology and Laboratory Medicine, University of Calgary, Calgary, AB, Canada.
- Division of Endocrinology and Metabolism, Department of Medicine, University of Calgary, Calgary, AB, Canada.
ORCID-Profile: Dennis J Orton
Zitieren
APA
Orton, D. J., Gifford, J. L., & Kline, G. A. (2026). Result Interpretation in Skewed Populations—Are Common Reference Intervals Inadequate?. The Journal of Applied Laboratory Medicine, 11(6), 1325-1336. https://doi.org/10.1093/jalm/jfag083
Vancouver
Orton DJ, Gifford JL, Kline GA. Result Interpretation in Skewed Populations—Are Common Reference Intervals Inadequate?. The Journal of Applied Laboratory Medicine. 2026;11(6):1325-1336. doi:10.1093/jalm/jfag083
BibTeX
@article{Orton2026,
author = {Orton, Dennis J and Gifford, Jessica L and Kline, Gregory A},
title = {Result Interpretation in Skewed Populations—Are Common Reference Intervals Inadequate?},
journal = {The Journal of Applied Laboratory Medicine},
year = {2026},
volume = {11},
number = {6},
pages = {1325--1336},
doi = {10.1093/jalm/jfag083}
}