EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Verification of a Novel High Sensitivity Troponin I Assay for Implementation in Rural Clinical Laboratories

Jacob A Wasylenko, Isolde Seiden-Long iD, Mireille Kattar, Heather A Paul, Miranda Brun, Mathew Estey, Poonam Reddy, Sean van Diepen iD, Albert K Y Tsui

The Journal of Applied Laboratory Medicine · 03.09.2025 · 10 (5) · 1254-1264

DOI: 10.1093/jalm/jfaf088 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift The Journal of Applied Laboratory Medicine, online erschienen am 23.07.2025. Verfasst von Jacob A Wasylenko und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, College of Health Science, University of Alberta, Edmonton, AB, C…. Hauptthemen laut MEDLINE: Troponin I, Laboratories, Clinical. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: QuidelOrtho.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

High sensitivity cardiac troponin (hs-cTn) assays run on instruments suitable for small laboratories are a desirable commodity for rural cardiovascular testing. The Quidel TriageTrue hs-cTnI assay was recently approved as a laboratory test in Canada. This study aimed to verify the analytical performance of this novel hs-cTnI assay and perform a head-to-head comparison with other hs-cTn assays.

Methods

A precision study was performed for 5–6 days with 5 replicates daily using quality control (QC) materials and patient plasma pools corresponding to the clinical decision thresholds. Linearity was assessed based on preparation of patient plasma pools at target troponin concentrations spanning the analytical measuring range. Fresh samples from coronary intensive care unit patients and healthy volunteers were used for head-to-head comparison of the TriageTrue hs-cTnI assay against several hs-cTnI (Beckman Access and Siemens Atellica) and hs-cTnT (Roche Cobas e801) assays. Assay-specific overall 99th percentile upper reference limits (URL) were used to assess analytical concordance. Risk reclassification was analytically assessed by comparing the decision cutpoints using the 2023 European Society of Cardiology (ESC) 0/1 h algorithm for the different hs-cTn assays.

Results

QC and patient samples demonstrated a coefficient of variation (CV) <10% near the overall 99th percentile URL. TriageTrue hs-cTnI assay has a >90% analytical concordance at the 99th percentile URL and <10% risk reclassification compared to the Beckman Access and Siemens Atellica hs-cTnI assays.

Conclusions

The novel TriageTrue hs-cTnI assay had comparable analytical performance as other hs-cTnI assays and can be considered in lower volume health care delivery settings with limited laboratory space.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin ILaboratories, ClinicalHumansCanadaQuality ControlReproducibility of ResultsBiomarkersSensitivity and Specificity

Substanzen

Troponin IBiomarkers

Autor:innen und Institutionen

  • Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, College of Health Science, University of Alberta, Edmonton, AB, Canada.
  • Alberta Precision Laboratories, Calgary and Edmonton, AB, Canada.
  • Department of Pathology and Laboratory Medicine, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.
  • Department of Critical Care Medicine and Division of Cardiology, Department of Medicine, Faculty of Medicine and Dentistry, College of Health Science, University of Alberta, Edmonton, AB, Canada.

ORCID-Profile: Isolde Seiden-Long, Sean van Diepen

Förderung

  • QuidelOrtho

Zitieren

APA

Wasylenko, J. A., Seiden-Long, I., Kattar, M., Paul, H. A., Brun, M., Estey, M., Reddy, P., van Diepen, S., & Tsui, A. K. Y. (2025). Verification of a Novel High Sensitivity Troponin I Assay for Implementation in Rural Clinical Laboratories. The Journal of Applied Laboratory Medicine, 10(5), 1254-1264. https://doi.org/10.1093/jalm/jfaf088

Vancouver

Wasylenko JA, Seiden-Long I, Kattar M, Paul HA, Brun M, Estey M, et al. Verification of a Novel High Sensitivity Troponin I Assay for Implementation in Rural Clinical Laboratories. The Journal of Applied Laboratory Medicine. 2025;10(5):1254-1264. doi:10.1093/jalm/jfaf088

BibTeX
@article{Wasylenko2025,
  author = {Wasylenko, Jacob A and Seiden-Long, Isolde and Kattar, Mireille and Paul, Heather A and Brun, Miranda and Estey, Mathew and Reddy, Poonam and van Diepen, Sean and Tsui, Albert K Y},
  title = {Verification of a Novel High Sensitivity Troponin I Assay for Implementation in Rural Clinical Laboratories},
  journal = {The Journal of Applied Laboratory Medicine},
  year = {2025},
  volume = {10},
  number = {5},
  pages = {1254--1264},
  doi = {10.1093/jalm/jfaf088}
}
Kostenlos starten →