EUVIMEDEUVIMED entdecken
Crossref

High-Sensitivity and Conventional Cardiac Troponin-I Assays in AL Amyloidosis

Maura C Dodge iD, Tatiana Prokaeva, Lisa Mendelson, Tracy Joshi, Vaishali Sanchorawala, Yachana Kataria iD

The Journal of Applied Laboratory Medicine · 03.03.2025 · 10 (2) · 315-324

DOI: 10.1093/jalm/jfae111 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Applied Laboratory Medicine, online erschienen am 04.11.2024. Verfasst von Maura C Dodge und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Laboratory Medicine, Boston Medical Center, Boston, MA, United States. Hauptthemen laut MEDLINE: Troponin I, Immunoglobulin Light-chain Amyloidosis. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Circulating cardiac troponin-I (cTnI) plays a crucial role in biomarker staging systems, offering important information for prognostification and risk stratification of patients with AL amyloidosis. High-sensitivity cTnI (HS-cTnI) assays have been introduced in practice; however, the data on the concordance between conventional and HS-cTnI and the utility of HS-cTnI in cardiac biomarker staging are lacking.

Methods

Seventy-eight consecutive patients with AL amyloidosis who were prospectively evaluated at the Boston University Amyloidosis Center from October 2022 through March 2023 were included. cTnI was measured using the Abbott Architect cTnI chemiluminescent microparticle immunoassay (CMIA) and HS-cTnI using the Abbott Alinity HS-cTnI CMIA assay. Assay results were compared by Deming regression and Bland–Altman analyses, and cardiac biomarker stages were assigned and compared using both assay results.

Results

Median cTnI and HS-cTnI concentrations were 13.0 and 7.0 ng/L, respectively. Bland–Altman analysis demonstrated a negative bias with HS-cTnI results (mean percent difference between assays: −49.8%) and the greatest variance occurring below 50 ng/L. Deming regression supported this negative discordance (slope, 0.66; intercept, −1.9). The use of HS-cTnI assay downgraded cardiac biomarker staging assignments from stage IIIA to stage II (n = 3) and from stage IIIB to stage II (n = 1).

Conclusions

Overall agreement was demonstrated; however, a negative bias for HS-cTnI assay was noted at low concentrations. The application of the conventional cTnI threshold of >100 ng/L to HS-cTnI-based Boston University cardiac staging showed a trend toward downgraded staging assignments. The prognostic utility of HS-cTnI assay in biomarker staging warrants further investigation in patients with AL amyloidosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin IImmunoglobulin Light-chain AmyloidosisHumansBiomarkersMaleFemaleMiddle AgedAgedProspective StudiesSensitivity and SpecificityImmunoassayPrognosis

Substanzen

Troponin IBiomarkers

Autor:innen und Institutionen

  • Department of Pathology and Laboratory Medicine, Boston Medical Center, Boston, MA, United States.
  • Amyloidosis Center, Boston University Chobanian and Avedisian School of Medicine, Boston, MA, United States.
  • Department of Pathology and Laboratory Medicine, Boston University Chobanian and Avedisian School of Medicine, Boston, MA, United States.

ORCID-Profile: Maura C Dodge, Yachana Kataria

Zitieren

APA

Dodge, M. C., Prokaeva, T., Mendelson, L., Joshi, T., Sanchorawala, V., & Kataria, Y. (2025). High-Sensitivity and Conventional Cardiac Troponin-I Assays in AL Amyloidosis. The Journal of Applied Laboratory Medicine, 10(2), 315-324. https://doi.org/10.1093/jalm/jfae111

Vancouver

Dodge MC, Prokaeva T, Mendelson L, Joshi T, Sanchorawala V, Kataria Y. High-Sensitivity and Conventional Cardiac Troponin-I Assays in AL Amyloidosis. The Journal of Applied Laboratory Medicine. 2025;10(2):315-324. doi:10.1093/jalm/jfae111

BibTeX
@article{Dodge2025,
  author = {Dodge, Maura C and Prokaeva, Tatiana and Mendelson, Lisa and Joshi, Tracy and Sanchorawala, Vaishali and Kataria, Yachana},
  title = {High-Sensitivity and Conventional Cardiac Troponin-I Assays in AL Amyloidosis},
  journal = {The Journal of Applied Laboratory Medicine},
  year = {2025},
  volume = {10},
  number = {2},
  pages = {315--324},
  doi = {10.1093/jalm/jfae111}
}
Kostenlos starten →