Maximizing Microsampling: Measurement of Comprehensive Metabolic and Lipid Panels Using a Novel Capillary Blood Collection Device
The Journal of Applied Laboratory Medicine · 02.11.2023 · 8 (6) · 1115-1126
DOI: 10.1093/jalm/jfad066 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Applied Laboratory Medicine, online erschienen am 25.09.2023. Verfasst von Bradley B Collier und 4 weiteren Autor:innen. Beteiligte Einrichtung: Center for Esoteric Testing, Labcorp, Burlington, NC, United States. Hauptthemen laut MEDLINE: Phlebotomy, Blood Specimen Collection. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Demand continues to grow for patient-centric sampling solutions that enable collection of small volumes of blood outside of healthcare facilities. Various technologies have been developed to facilitate sample collection but gaps in knowledge remain, preventing these technologies from replacing standard venipuncture.
Methods
A novel blood collection device, Touch Activated Phlebotomy (TAP) II® from YourBio Health, and standard fingerstick collection using a BD Microtainer® were utilized to collect capillary serum samples. Measurements of a comprehensive metabolic and lipid panels were measured on these samples and compared to results from venous serum samples that were collected in parallel. Hemolysis was used to assess sample quality. Sample volumes obtained from self-collected TAP II samples were also determined.
Results
Correlation of capillary serum with respect to venous serum was demonstrated (R > 0.9) for professionally collected TAP II samples, self-collected TAP II samples, and professionally collected fingerstick samples for alkaline phosphatase, alanine aminotransferase, aspartate aminotransferase, blood urea nitrogen, cholesterol, high-density lipoprotein, total bilirubin, and triglycerides. Results for creatinine demonstrated acceptable correlation, however, a consistent negative bias was observed. Biases (with unacceptable correlations) were also observed for measurements of carbon dioxide and potassium. Correlative results for albumin were not consistently acceptable across the collection techniques utilized while the remaining analytes tested did not demonstrate acceptable correlations under any condition. Correlation results, however, would improve with a wider distribution of analyte concentrations.
Conclusions
Collections of small volumes of liquid blood continue to show potential as a patient-centric solution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Center for Esoteric Testing, Labcorp, Burlington, NC, United States.
Zitieren
APA
Collier, B. B., Brandon, W. C., Chappell, M. R., Kovach, P. M., & Grant, R. P. (2023). Maximizing Microsampling: Measurement of Comprehensive Metabolic and Lipid Panels Using a Novel Capillary Blood Collection Device. The Journal of Applied Laboratory Medicine, 8(6), 1115-1126. https://doi.org/10.1093/jalm/jfad066
Vancouver
Collier BB, Brandon WC, Chappell MR, Kovach PM, Grant RP. Maximizing Microsampling: Measurement of Comprehensive Metabolic and Lipid Panels Using a Novel Capillary Blood Collection Device. The Journal of Applied Laboratory Medicine. 2023;8(6):1115-1126. doi:10.1093/jalm/jfad066
BibTeX
@article{Collier2023,
author = {Collier, Bradley B and Brandon, Whitney C and Chappell, Matthew R and Kovach, Peyton M and Grant, Russell P},
title = {Maximizing Microsampling: Measurement of Comprehensive Metabolic and Lipid Panels Using a Novel Capillary Blood Collection Device},
journal = {The Journal of Applied Laboratory Medicine},
year = {2023},
volume = {8},
number = {6},
pages = {1115--1126},
doi = {10.1093/jalm/jfad066}
}
EUVIMED