EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Successful Detection of Delta and Omicron Variants of SARS-CoV-2 by Veterinary Diagnostic Laboratory Participants in an Interlaboratory Comparison Exercise

Kaiping Deng, Sarah M Nemser, Kirstin Frost, Laura B Goodman, Hon S Ip, Mary Lea Killian, Jodie Ulaszek, Shannon Kiener, Matthew Kmet, Steffen Uhlig, Karina Hettwer, Bertrand Colson und 6 weitere

The Journal of Applied Laboratory Medicine · 2023

DOI: 10.1093/jalm/jfad018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Applied Laboratory Medicine, 2023. Verfasst von Kaiping Deng und 17 weiteren Autor:innen. Beteiligte Einrichtung: Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, Bedford Park, IL, United States. Hauptthemen laut MEDLINE: SARS-CoV-2, COVID-19. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Intramural FDA HHS, FDA HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Throughout the COVID-19 pandemic, veterinary diagnostic laboratories have tested diagnostic samples for SARS-CoV-2 both in animals and over 6 million human samples. An evaluation of the performance of those laboratories is needed using blinded test samples to ensure that laboratories report reliable data to the public. This interlaboratory comparison exercise (ILC3) builds on 2 prior exercises to assess whether veterinary diagnostic laboratories can detect Delta and Omicron variants spiked in canine nasal matrix or viral transport medium.

Methods

The ILC organizer was an independent laboratory that prepared inactivated Delta variant at levels of 25 to 1000 copies per 50 µL of nasal matrix for blinded analysis. Omicron variant at 1000 copies per 50 µL of transport medium was also included. Feline infectious peritonitis virus (FIPV) RNA was used as a confounder for specificity assessment. Fourteen test samples were prepared for each participant. Participants used their routine diagnostic procedures for RNA extraction and real-time reverse transcriptase-PCR. Results were analyzed according to International Organization for Standardization (ISO) 16140–2:2016.

Results

Overall, laboratories demonstrated 93% detection for Delta and 97% for Omicron at 1000 copies per 50 µL. Specificity was 97% for blank samples and 100% for blank samples with FIPV. No differences in Cycle Threshold (Ct) values were significant for samples with the same virus levels between N1 and N2 markers, nor between the 2 variants.

Conclusions

The results indicated that all ILC3 participants were able to detect both Delta and Omicron variants. The canine nasal matrix did not significantly affect SARS-CoV-2 detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SARS-CoV-2COVID-19CatsHumansAnimalsDogsLaboratoriesPandemicsRNACOVID-19 Testing

Substanzen

RNA

Autor:innen und Institutionen

  • Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, Bedford Park, IL, United States.
  • Center for Veterinary Medicine, U.S. Food and Drug Administration, Laurel, MD, United States.
  • QuoData - Quality & Statistics, Dresden, Germany.
  • College of Veterinary Medicine, Cornell University, Ithaca, NY, United States.
  • National Wildlife Health Center, U.S. Geological Survey, Madison, WI, United States.
  • National Veterinary Services Laboratories, Animal and Plant Health Inspection Service, U.S. Department of Agriculture, Ames, IA, United States.

ORCID-Profile: Andriy Tkachenko

Förderung

  • Intramural FDA HHS
  • FDA HHS

Zitieren

APA

Deng, K., Nemser, S. M., Frost, K., Goodman, L. B., Ip, H. S., Killian, M. L., Ulaszek, J., Kiener, S., Kmet, M., Uhlig, S., Hettwer, K., Colson, B., Nichani, K., Schlierf, A., Tkachenko, A., Miller, M. R., Reddy, R., & Tyson, G. H. (2023). Successful Detection of Delta and Omicron Variants of SARS-CoV-2 by Veterinary Diagnostic Laboratory Participants in an Interlaboratory Comparison Exercise. The Journal of Applied Laboratory Medicine. https://doi.org/10.1093/jalm/jfad018

Vancouver

Deng K, Nemser SM, Frost K, Goodman LB, Ip HS, Killian ML, et al. Successful Detection of Delta and Omicron Variants of SARS-CoV-2 by Veterinary Diagnostic Laboratory Participants in an Interlaboratory Comparison Exercise. The Journal of Applied Laboratory Medicine. 2023. doi:10.1093/jalm/jfad018

BibTeX
@article{Deng2023,
  author = {Deng, Kaiping and Nemser, Sarah M and Frost, Kirstin and Goodman, Laura B and Ip, Hon S and Killian, Mary Lea and Ulaszek, Jodie and Kiener, Shannon and Kmet, Matthew and Uhlig, Steffen and Hettwer, Karina and Colson, Bertrand and Nichani, Kapil and Schlierf, Anja and Tkachenko, Andriy and Miller, Megan R and Reddy, Ravinder and Tyson, Gregory H},
  title = {Successful Detection of Delta and Omicron Variants of SARS-CoV-2 by Veterinary Diagnostic Laboratory Participants in an Interlaboratory Comparison Exercise},
  journal = {The Journal of Applied Laboratory Medicine},
  year = {2023},
  doi = {10.1093/jalm/jfad018}
}
Kostenlos starten →