Fachartikel in der Zeitschrift International Journal for Quality in Health Care, online erschienen am 22.09.2026. Verfasst von Huma Shakoor und 5 weiteren Autor:innen. Beteiligte Einrichtung: Health Safety & Environment, Peshawar Institute of Cardiology, Peshawar, Pakistan. Hauptthemen laut MEDLINE: Quality Improvement, Tertiary Care Centers, Certification, Cardiac Care Facilities. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

External quality frameworks such as ISO 9001 certification lay the foundation for healthcare quality, patient safety, and operational efficiency, but sustained improvement depends on leadership, a culture of safety, and systems that translate assurance into ongoing learning. Evidence on this transition from low- and middle-income countries, particularly in specialized cardiac care, remains limited.

Methods

A retrospective longitudinal analysis of quality assurance data from January 2020 to December 2025 was conducted at the Peshawar Institute of Cardiology (PIC-MTI), Pakistan. Independent-samples t-tests, one-way ANOVA, and Difference-in-Differences (DiD) modeling were applied, with three regional hospitals of similar bed capacity and patient volume serving as a comparison group.

Results

Following ISO 9001 certification (February 2022), monthly mortality within 48 h declined from 2.8% (SD ± 0.4%) to 1.9% (SD ± 0.3%) (t = 3.21, df = 58, P = .004). Hospital-acquired infections (HAIs) fell from 3.2% to 2.0% (t = 4.15, P = .002), reaching 1.3% by 2025, with zero CLABSIs recorded in the final quarter following the mid-period intensification of the infection-control bundle. Mean length of stay decreased from 6.2 to 4.7 days [ANOVA: F(2,57) = 8.76, P < .001]. Patient satisfaction rose from 78% to above 90%. DiD modeling found a net 30% reduction in HAIs and 20% reduction in length of stay (LOS) associated with the certification process relative to the comparison trajectory.

Conclusions

ISO 9001 certification, undertaken alongside deliberate investment in leadership, a culture of safety, and structured use of data, is associated with sustained improvements in clinical outcomes and operational efficiency at a resource-limited cardiac care center that has not yet pursued formal Joint Commission International (JCI) accreditation but is using JCI’s standards, as one example of an internationally recognized framework, to guide its preparation. The pattern observed here suggests that a learning quality management system, and not any single certificate or accreditation status, is what converts external standards into measurable gains, offering a replicable model for institutions considering how to move from quality assurance toward continual quality improvement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quality ImprovementTertiary Care CentersCertificationCardiac Care FacilitiesPakistanHumansRetrospective StudiesCross InfectionPatient SafetyLongitudinal StudiesHospital MortalityLeadership

Stichwörter der Autor:innen

ISO 9001 certificationJoint Commission Internationalcardiac carehospital accreditationleadershiplow- and middle-income countriesquality improvementquality management system

Autor:innen und Institutionen

  • Health Safety & Environment, Peshawar Institute of Cardiology, Peshawar, Pakistan.
  • Department of Health Sciences, University of Debrecen, Debrecen, Hungary.
  • Cardiac Surgery, Peshawar Institute of Cardiology, Peshawar, Pakistan.
  • Quality Assurance Department, Peshawar Institute of Cardiology, Peshawar, Pakistan.

ORCID-Profile: Huma Shakoor, Waqas Naseem, Tabish Rasool

Zitieren

APA

Shakoor, H., Naseem, W., Ahmed Shah, S. S., Shah, N., Karim, A., & Rasool, T. (2026). ISO 9001 and JCI preparedness as drivers of quality improvement at a tertiary cardiac care center: a 5-year analysis from Pakistan. International Journal for Quality in Health Care, 38(4). https://doi.org/10.1093/intqhc/mzag154

Vancouver

Shakoor H, Naseem W, Ahmed Shah SS, Shah N, Karim A, Rasool T. ISO 9001 and JCI preparedness as drivers of quality improvement at a tertiary cardiac care center: a 5-year analysis from Pakistan. International Journal for Quality in Health Care. 2026;38(4). doi:10.1093/intqhc/mzag154

BibTeX
@article{Shakoor2026,
  author = {Shakoor, Huma and Naseem, Waqas and Ahmed Shah, Syed Shahkar and Shah, Naveed and Karim, Abdul and Rasool, Tabish},
  title = {ISO 9001 and JCI preparedness as drivers of quality improvement at a tertiary cardiac care center: a 5-year analysis from Pakistan},
  journal = {International Journal for Quality in Health Care},
  year = {2026},
  volume = {38},
  number = {4},
  doi = {10.1093/intqhc/mzag154}
}
Kostenlos starten →