Assessment of a novel semi-automated dataset for large-scale surveillance of central venous catheter–related mechanical complications
International Journal for Quality in Health Care · 13.04.2026 · 38 (2)
DOI: 10.1093/intqhc/mzag080 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal for Quality in Health Care, online erschienen am 05.06.2026. Verfasst von Emilia Ängeby und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences, Lund University, Lund, Sweden. Hauptthemen laut MEDLINE: Catheterization, Central Venous, Electronic Health Records, Central Venous Catheters. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swedish government, Swedish National Health Service, Swedish Patient Insurance.
Abstract (Originalsprache)
Background
The aim of this study was to examine whether a novel semi-automated dataset based on electronic health record documentation can be used for surveillance of central venous catheter-related mechanical complications (failed catheterization, bleeding, cardiac arrhythmia, pneumothorax and nerve injury) within 24 h of catheterization.
Methods
The semi-automated dataset comprised a fully automated extraction of clinical documentation from the electronic health record supplemented with a minor manual review aimed at identifying pneumothoraces, as these are rarely diagnosed at the time of insertion but rather after a postprocedural chest X-ray. To assess surveillance performance, we compared the number of mechanical complications between the semi-automated and manually evaluated datasets for the same cohort and study period, focusing on agreement in aggregate counts. Comparisons were made at the group level only, without enforcing insertion-by-insertion matching.
Results
A total of 12 667 insertions were included. Minor mechanical complications occurred in 615 (4.9%) of the insertions in the semi-automated dataset and in 645 (5.1%) of the insertions in the manually validated dataset. Major mechanical complications occurred in 44 (0.35%) of the insertions in the semi-automated dataset compared to 48 (0.38%) in the manually validated dataset.
Conclusion
A semi-automated dataset based on electronic health record documentation provides sufficiently accurate surveillance of central catheterization-related mechanical complications at the group level. Despite minor discrepancies, the semi-automated method enhances efficiency, scalability, and supports continuous real-time quality assurance. The potential underestimation of complication rates is offset by the possibility of robust real-time quality assurance in registries and a substantial analytical power in scientific studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Clinical Sciences, Lund University, Lund, Sweden.
- Department of Intensive and Perioperative Care, Skåne University Hospital, Lund, Sweden.
- Department of Anaesthesia and Perfusion, The Prince Charles Hospital, Brisbane, Queensland, Australia.
- Department of Cardiothoracic Surgery, Anaesthesia and Intensive Care, Skåne University Hospital, Lund, Sweden.
ORCID-Profile: Emilia Ängeby
Förderung
- Swedish government
- Swedish National Health Service
- Swedish Patient Insurance
Zitieren
APA
Ängeby, E., Adrian, M., Lazarevic Lindblad, M., Borgquist, O., & Kander, T. (2026). Assessment of a novel semi-automated dataset for large-scale surveillance of central venous catheter–related mechanical complications. International Journal for Quality in Health Care, 38(2). https://doi.org/10.1093/intqhc/mzag080
Vancouver
Ängeby E, Adrian M, Lazarevic Lindblad M, Borgquist O, Kander T. Assessment of a novel semi-automated dataset for large-scale surveillance of central venous catheter–related mechanical complications. International Journal for Quality in Health Care. 2026;38(2). doi:10.1093/intqhc/mzag080
BibTeX
@article{ngeby2026,
author = {Ängeby, Emilia and Adrian, Maria and Lazarevic Lindblad, Mathias and Borgquist, Ola and Kander, Thomas},
title = {Assessment of a novel semi-automated dataset for large-scale surveillance of central venous catheter–related mechanical complications},
journal = {International Journal for Quality in Health Care},
year = {2026},
volume = {38},
number = {2},
doi = {10.1093/intqhc/mzag080}
}