Real-life Assessment of BioFire FilmArray Pneumonia Panel in Adults Hospitalized With Respiratory Illness
The Journal of Infectious Diseases · 12.01.2024 · 229 (1) · 214-222
DOI: 10.1093/infdis/jiad221 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Infectious Diseases, online erschienen am 27.06.2023. Verfasst von Ann R Falsey und 5 weiteren Autor:innen. Beteiligte Einrichtung: Infectious Diseases, Department of Medicine. Hauptthemen laut MEDLINE: Respiratory Tract Infections, Viruses, Pneumonia. Die Arbeit wurde bisher 60-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIEHS NIH HHS, NIAID NIH HHS, National Institute of Allergy and Infectious Disease.
Abstract (Originalsprache)
Background
Inability to identify the microbial etiology of lower respiratory tract infection leads to unnecessary antibiotic use. We evaluated the utility of the BioFire FilmArray Pneumonia Panel (BioFire PN) to inform microbiologic diagnosis.
Methods
Hospitalized adults with respiratory illness were recruited; sputa and clinical/laboratory data were collected. Sputa were cultured for bacteria and tested with BioFire PN. Microbial etiology was adjudicated by 4 physicians. Bacterial polymerase chain reaction (PCR) was compared with culture and clinical adjudication.
Results
Of 298 sputa tested, BioFire PN detected significantly more pathogens (350 bacteria, 16 atypicals, and 164 viruses) than sputum culture plus any standard-of-care testing (91% vs 60%, P < .0001). When compared with culture, the sensitivity of BioFire PN for individual bacteria was 46% to 100%; specificity, 61% to 100%; and negative predictive value, 92% to 100%. Cases were adjudicated as viral (n = 58) and bacterial (n = 100). PCR detected bacteria in 55% of viral cases and 95% of bacterial (P < .0001). High serum procalcitonin and bacterial adjudication were more often associated with sputa with 106 or 107 copies detected.
Conclusions
Multiplex PCR testing of sputa for bacteria is useful to rule out bacterial infection with added value to detect viruses and atypical bacteria.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Infectious Diseases, Department of Medicine.
- Department of Pulmonary and Critical Medicine, University of Rochester.
- Infectious Disease Unit, Rochester General Hospital, Rochester, New York, USA.
Förderung
- NIEHS NIH HHS
- NIAID NIH HHS
- National Institute of Allergy and Infectious Disease
Zitieren
APA
Falsey, A. R., Branche, A. R., Croft, D. P., Formica, M. A., Peasley, M. R., & Walsh, E. E. (2024). Real-life Assessment of BioFire FilmArray Pneumonia Panel in Adults Hospitalized With Respiratory Illness. The Journal of Infectious Diseases, 229(1), 214-222. https://doi.org/10.1093/infdis/jiad221
Vancouver
Falsey AR, Branche AR, Croft DP, Formica MA, Peasley MR, Walsh EE. Real-life Assessment of BioFire FilmArray Pneumonia Panel in Adults Hospitalized With Respiratory Illness. The Journal of Infectious Diseases. 2024;229(1):214-222. doi:10.1093/infdis/jiad221
BibTeX
@article{Falsey2024,
author = {Falsey, Ann R and Branche, Angela R and Croft, Daniel P and Formica, Maria A and Peasley, Michael R and Walsh, Edward E},
title = {Real-life Assessment of BioFire FilmArray Pneumonia Panel in Adults Hospitalized With Respiratory Illness},
journal = {The Journal of Infectious Diseases},
year = {2024},
volume = {229},
number = {1},
pages = {214--222},
doi = {10.1093/infdis/jiad221}
}
EUVIMED