EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

CFD-based analysis of chimney performance optimization for the Manzanares pilot plant

Pinar Mert Cuce, Erdem Cuce, Saad Alshahrani

International Journal of Low-Carbon Technologies · 27.01.2026 · 21

DOI: 10.1093/ijlct/ctag026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Low-Carbon Technologies, online erschienen am 19.03.2026. Verfasst von Pinar Mert Cuce und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deanship of Research and Graduate Studies at King Khalid University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This research conducts an extensive computational fluid dynamics (CFD) analysis aimed at optimizing the geometric configuration of solar chimney power plants (SCPPs), with particular emphasis on the Manzanares pilot plant. The research analyses the effects of chimney diameter and divergent chimney design on system performance under steady-state conditions at 1000 W/m2 solar irradiance and 300 K ambient temperature. A validated three-dimensional CFD model with a 90° symmetry sector is developed in ANSYS FLUENT. The model is verified through mesh independence and benchmarked against experimental results, showing excellent agreement with measured power output and airflow velocity. The results demonstrate that chimney geometry is a dominant performance-governing factor in large-scale SCPPs. Increasing the chimney diameter up to 2.5 times the reference value enhances the power output by 97%, reaching ~110 kW; further enlargement leads to performance deterioration due to reduced pressure potential at the turbine. More importantly, the adoption of a divergent chimney configuration yields a substantial performance improvement. An optimal chimney exit-to-inlet area ratio of 4 increases the power output to 369.4 kW, corresponding to a 5.6-fold enhancement compared to the reference cylindrical chimney. At this optimal configuration, the maximum air velocity and mass flow rate reach 28.7 m/s and 2137.8 kg/s, respectively. These findings demonstrate that multifold power enhancement can be achieved through aerodynamic optimization of chimney geometry alone, without increasing chimney height, offering a practical, cost-effective, and structurally safer design pathway for future large-scale SCPP installations.

Förderung

  • Deanship of Research and Graduate Studies at King Khalid University

Zitieren

APA

Cuce, P. M., Cuce, E., & Alshahrani, S. (2026). CFD-based analysis of chimney performance optimization for the Manzanares pilot plant. International Journal of Low-Carbon Technologies, 21. https://doi.org/10.1093/ijlct/ctag026

Vancouver

Cuce PM, Cuce E, Alshahrani S. CFD-based analysis of chimney performance optimization for the Manzanares pilot plant. International Journal of Low-Carbon Technologies. 2026;21. doi:10.1093/ijlct/ctag026

BibTeX
@article{Cuce2026,
  author = {Cuce, Pinar Mert and Cuce, Erdem and Alshahrani, Saad},
  title = {CFD-based analysis of chimney performance optimization for the Manzanares pilot plant},
  journal = {International Journal of Low-Carbon Technologies},
  year = {2026},
  volume = {21},
  doi = {10.1093/ijlct/ctag026}
}
Kostenlos starten →