EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comprehensive hemodynamic assessment of the Fontan pathway using four-dimensional flow magnetic resonance imaging

Muneaki Matsubara, Thibault Schaeffer, Jonas Palm, Teresa Lemmen, Christina Ruda, Heiko Stern, Nerejda Shehu, Shohei Miyazaki, Kohei Suzuki, Teruyasu Nishino, Keiichi Itatani, Christian Meierhofer und 2 weitere

Interdisciplinary CardioVascular and Thoracic Surgery · 30.10.2026

DOI: 10.1093/icvts/ivag293 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, online erschienen am 30.10.2026. Verfasst von Muneaki Matsubara und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Congenital and Pediatric Heart Surgery, TUM University Hospital, German Heart Center, Munich, Germany. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Conventional hemodynamic assessment of Fontan circulation relies on limited quantitative measurements. We evaluated the feasibility and clinical value of comprehensive flow visualization using four-dimensional flow magnetic resonance imaging to characterize patient-specific hemodynamic patterns in extracardiac total cavopulmonary connection.

Methods

Eight patients with extracardiac total cavopulmonary connection underwent four-dimensional flow magnetic resonance imaging at a median of 13.7 years postoperatively (interquartile range: 9.0-16.4 years). The Fontan pathway was segmented into five regions: extracardiac conduit, superior vena cava, central confluence, left pulmonary artery, and right pulmonary artery. Energy loss, maximum velocity, and kinetic energy were quantified for each segment using iTFlow software. Clinical outcomes were assessed during follow-up.

Results

Median age at total cavopulmonary connection was 1.8 years (interquartile range: 1.5-3.5), with 18 mm conduits in seven patients and 22 mm conduit in one patient. During a median follow-up of 17.3 years, two patients underwent re-operation after magnetic resonance imaging evaluation (tricuspid valve replacement and ascending aortic reconstruction); all remained alive without Fontan failure. Energy loss differed significantly across segments (p = 0.011), being highest in the conduit and central confluence, with remarkable inter-patient variability superimposed (conduit values varying 35-fold from 0.025 to 0.887 mW). Maximum velocity strongly correlated with energy loss (r = 0.92, p = 0.001), suggesting velocity may serve as an accessible surrogate. Atrioventricular valve regurgitation severity did not consistently correlate with energy loss.

Conclusions

Four-dimensional flow magnetic resonance imaging with iTFlow software enables comprehensive hemodynamic assessment throughout the Fontan pathway, revealing substantial patient-specific heterogeneity in energy efficiency. With larger cohorts and correlation with clinical outcomes, this technique may become a valuable screening tool for post-Fontan evaluation and long-term surveillance.

Schlagwörter

Stichwörter der Autor:innen

Fontan procedureblood flow velocityhemodynamicsmagnetic resonance imaginguniventricular heart

Autor:innen und Institutionen

  • Department of Congenital and Pediatric Heart Surgery, TUM University Hospital, German Heart Center, Munich, Germany.
  • Division of Congenital and Pediatric Heart Surgery, University Hospital of Munich, Ludwig- Maximilians-Universität München, Munich, Germany.
  • Europäisches Kinderherzzentrum München, Munich 80636, Germany.
  • Department of Cardiovascular Surgery, Tokyo Metropolitan Children's Medical Center, Tokyo 183-8561, Japan.
  • Department of Congenital Heart Disease and Pediatric Cardiology, TUM University Hospital, German Heart Center, Munich 80636, Germany.
  • Cardio Flow Design Inc., Tokyo 102-0082, Japan.

Zitieren

APA

Matsubara, M., Schaeffer, T., Palm, J., Lemmen, T., Ruda, C., Stern, H., Shehu, N., Miyazaki, S., Suzuki, K., Nishino, T., Itatani, K., Meierhofer, C., Hörer, J., & Ono, M. (2026). Comprehensive hemodynamic assessment of the Fontan pathway using four-dimensional flow magnetic resonance imaging. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivag293

Vancouver

Matsubara M, Schaeffer T, Palm J, Lemmen T, Ruda C, Stern H, et al. Comprehensive hemodynamic assessment of the Fontan pathway using four-dimensional flow magnetic resonance imaging. Interdisciplinary CardioVascular and Thoracic Surgery. 2026. doi:10.1093/icvts/ivag293

BibTeX
@article{Matsubara2026,
  author = {Matsubara, Muneaki and Schaeffer, Thibault and Palm, Jonas and Lemmen, Teresa and Ruda, Christina and Stern, Heiko and Shehu, Nerejda and Miyazaki, Shohei and Suzuki, Kohei and Nishino, Teruyasu and Itatani, Keiichi and Meierhofer, Christian and Hörer, Jürgen and Ono, Masamichi},
  title = {Comprehensive hemodynamic assessment of the Fontan pathway using four-dimensional flow magnetic resonance imaging},
  journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
  year = {2026},
  doi = {10.1093/icvts/ivag293}
}
Kostenlos starten →