Transcatheter coil embolization for proximal thoracic aortic pseudoaneurysms: a case series with mid-term clinical and imaging follow-up
Interdisciplinary CardioVascular and Thoracic Surgery · 02.11.2026
DOI: 10.1093/icvts/ivag290 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, online erschienen am 02.11.2026. Verfasst von Luca Di Marco und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiac Surgery, Cardiac Surgery Department, IRCCS, Azienda Ospedaliero-Universitaria di Bologna. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
Proximal aortic pseudoaneurysms represent a life-threatening complication of cardiac surgery. Traditional redo surgery is associated with substantial operative risk, while conventional endovascular stenting is often precluded by complex anatomy. We evaluated the clinical feasibility, safety, and durability of transcatheter coil embolization for proximal aortic pseudoaneurysms in a high-risk cohort.
Methods
Between September 2020 and February 2024, nine consecutive high-risk patients with proximal aortic pseudoaneurysms underwent transcatheter coil embolization at our institution. Preoperative risk profiles, procedural characteristics, intra-hospital outcomes, and serial computed tomography angiography follow-up datasets were retrospectively analyzed.
Results
The cohort was predominantly male (88.9%), with a mean age of 69.1±13 years and a mean Logistic EuroSCORE of 22.82%±18.76%. Patients had undergone a mean of 2.56 previous aortic procedures. Access routes included transfemoral (n = 6), transapical (n = 3), axillary (n = 1), and transbrachial (n = 1) approaches. Stent-assisted embolization was deployed in two cases. Technical success was achieved in all cases, with a median post-procedural stay of six days. Mean follow-up was 16±14.8 months. Serial imaging demonstrated stable sac dimensions in all patients, with no local recurrences. All-cause mortality was 33.3% (n = 3), and all deaths were attributed to sudden systemic events unrelated to target lesion failure or rupture.
Conclusions
Transcatheter coil embolization appears to be a safe, technically feasible, and durable alternative for the exclusion of proximal aortic pseudoaneurysms. In this small high-risk cohort, the technique achieved excellent local control and mid-term structural stability in fragile, multi-operated patients who were not candidates for conventional open surgery.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiac Surgery, Cardiac Surgery Department, IRCCS, Azienda Ospedaliero-Universitaria di Bologna.
- Department of Medical and Surgical Sciences, DIMEC, Alma Mater Studiorum - University of Bologna, Bologna.
- Pediatric and Adult CardioThoracic and Vascular, Oncohematologic and Emergency Radiology Unit-IRCCS Azienda Ospedaliero-Universitaria di Bologna.
Zitieren
APA
Di Marco, L., Piperata, A., Snaidero, S., Cocozza, M. A., Attinà, D., Deniku, M., Lovato, L., Pacini, D., & Buia, F. (2026). Transcatheter coil embolization for proximal thoracic aortic pseudoaneurysms: a case series with mid-term clinical and imaging follow-up. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivag290
Vancouver
Di Marco L, Piperata A, Snaidero S, Cocozza MA, Attinà D, Deniku M, et al. Transcatheter coil embolization for proximal thoracic aortic pseudoaneurysms: a case series with mid-term clinical and imaging follow-up. Interdisciplinary CardioVascular and Thoracic Surgery. 2026. doi:10.1093/icvts/ivag290
BibTeX
@article{DiMarco2026,
author = {Di Marco, Luca and Piperata, Antonio and Snaidero, Silvia and Cocozza, Maria Adriana and Attinà, Domenico and Deniku, Megan and Lovato, Luigi and Pacini, Davide and Buia, Francesco},
title = {Transcatheter coil embolization for proximal thoracic aortic pseudoaneurysms: a case series with mid-term clinical and imaging follow-up},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2026},
doi = {10.1093/icvts/ivag290}
}
EUVIMED