EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Left Ventricular Outflow Tract Diameter Variability and Prosthesis-Patient Mismatch: A Simulation Study

J W Taco Boltje iD, Bart J J Velders iD, Joseph F Sabik, Jae K Oh, Saki Ito iD, Robert J M Klautz iD, Michiel D Vriesendorp

Interdisciplinary CardioVascular and Thoracic Surgery · 05.05.2026 · 41 (5)

DOI: 10.1093/icvts/ivag133 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, online erschienen am 11.05.2026. Verfasst von J W Taco Boltje und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden 2333 ZA, The Netherlands. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Heart Valve Prosthesis Implantation, Aortic Valve, Models, Cardiovascular. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A recent discussion that highlighted the differences between the reported effective orifice area and corresponding incidence of prosthesis-patient mismatch within the 1- and 7-year results of the PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Trial of the Avalus valve has once again emphasized the instability of such measurements. The effective orifice area, calculated using the continuity equation through measurements of the left ventricular outflow tract diameter, is highly susceptible to measurement variability, as previously demonstrated in literature through both intra- and interobserver variability. To illustrate this problem, a simulation was performed in which the left ventricular outflow tract diameter was systematically altered by −2 mm, −1 mm, 0 mm, +1 mm, and +2 mm. Subsequently, the proportion of severe prosthesis-patient mismatch was recalculated and varied between 13.3%, 6.2%, 3.1% (original), 1.2%, and 0.3%, respectively. These findings demonstrate that small but clinically realistic variability in left ventricular outflow tract measurements can significantly affect the presence of prosthesis-patient mismatch. A measurement variability of 1 mm can nearly double or halve the prevalence of severe prosthesis-patient mismatch. This illustrates that prosthesis-patient mismatch, in its current form, is highly unstable and that indexed effective orifice area-based prosthesis-patient mismatch should not be used in isolation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisHeart Valve Prosthesis ImplantationAortic ValveModels, CardiovascularComputer SimulationHeart VentriclesBioprosthesisHumansProsthesis Design

Stichwörter der Autor:innen

aortic valve replacementechocardiographyleft ventricular outflow tract diametermeasurement variabilityprosthesis-patient mismatch

Autor:innen und Institutionen

  • Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden 2333 ZA, The Netherlands.
  • Department of Surgery, University Hospitals, Case Western Reserve University School of Medicine, Cleveland, OH 44106-7060, United States.
  • Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905-0001, United States.
  • Department of Cardiothoracic Surgery, Amsterdam University Medical Center, Amsterdam 1105 AZ, The Netherlands.

ORCID-Profile: J W Taco Boltje, Bart J J Velders, Saki Ito, Robert J M Klautz

Zitieren

APA

Boltje, J. W. T., Velders, B. J. J., Sabik, J. F., Oh, J. K., Ito, S., Klautz, R. J. M., & Vriesendorp, M. D. (2026). Left Ventricular Outflow Tract Diameter Variability and Prosthesis-Patient Mismatch: A Simulation Study. Interdisciplinary CardioVascular and Thoracic Surgery, 41(5). https://doi.org/10.1093/icvts/ivag133

Vancouver

Boltje JWT, Velders BJJ, Sabik JF, Oh JK, Ito S, Klautz RJM, et al. Left Ventricular Outflow Tract Diameter Variability and Prosthesis-Patient Mismatch: A Simulation Study. Interdisciplinary CardioVascular and Thoracic Surgery. 2026;41(5). doi:10.1093/icvts/ivag133

BibTeX
@article{Boltje2026,
  author = {Boltje, J W Taco and Velders, Bart J J and Sabik, Joseph F and Oh, Jae K and Ito, Saki and Klautz, Robert J M and Vriesendorp, Michiel D},
  title = {Left Ventricular Outflow Tract Diameter Variability and Prosthesis-Patient Mismatch: A Simulation Study},
  journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
  year = {2026},
  volume = {41},
  number = {5},
  doi = {10.1093/icvts/ivag133}
}
Kostenlos starten →