Left Ventricular Outflow Tract Diameter Variability and Prosthesis-Patient Mismatch: A Simulation Study
Interdisciplinary CardioVascular and Thoracic Surgery · 05.05.2026 · 41 (5)
DOI: 10.1093/icvts/ivag133 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, online erschienen am 11.05.2026. Verfasst von J W Taco Boltje und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden 2333 ZA, The Netherlands. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Heart Valve Prosthesis Implantation, Aortic Valve, Models, Cardiovascular. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
A recent discussion that highlighted the differences between the reported effective orifice area and corresponding incidence of prosthesis-patient mismatch within the 1- and 7-year results of the PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Trial of the Avalus valve has once again emphasized the instability of such measurements. The effective orifice area, calculated using the continuity equation through measurements of the left ventricular outflow tract diameter, is highly susceptible to measurement variability, as previously demonstrated in literature through both intra- and interobserver variability. To illustrate this problem, a simulation was performed in which the left ventricular outflow tract diameter was systematically altered by −2 mm, −1 mm, 0 mm, +1 mm, and +2 mm. Subsequently, the proportion of severe prosthesis-patient mismatch was recalculated and varied between 13.3%, 6.2%, 3.1% (original), 1.2%, and 0.3%, respectively. These findings demonstrate that small but clinically realistic variability in left ventricular outflow tract measurements can significantly affect the presence of prosthesis-patient mismatch. A measurement variability of 1 mm can nearly double or halve the prevalence of severe prosthesis-patient mismatch. This illustrates that prosthesis-patient mismatch, in its current form, is highly unstable and that indexed effective orifice area-based prosthesis-patient mismatch should not be used in isolation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden 2333 ZA, The Netherlands.
- Department of Surgery, University Hospitals, Case Western Reserve University School of Medicine, Cleveland, OH 44106-7060, United States.
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905-0001, United States.
- Department of Cardiothoracic Surgery, Amsterdam University Medical Center, Amsterdam 1105 AZ, The Netherlands.
ORCID-Profile: J W Taco Boltje, Bart J J Velders, Saki Ito, Robert J M Klautz
Zitieren
APA
Boltje, J. W. T., Velders, B. J. J., Sabik, J. F., Oh, J. K., Ito, S., Klautz, R. J. M., & Vriesendorp, M. D. (2026). Left Ventricular Outflow Tract Diameter Variability and Prosthesis-Patient Mismatch: A Simulation Study. Interdisciplinary CardioVascular and Thoracic Surgery, 41(5). https://doi.org/10.1093/icvts/ivag133
Vancouver
Boltje JWT, Velders BJJ, Sabik JF, Oh JK, Ito S, Klautz RJM, et al. Left Ventricular Outflow Tract Diameter Variability and Prosthesis-Patient Mismatch: A Simulation Study. Interdisciplinary CardioVascular and Thoracic Surgery. 2026;41(5). doi:10.1093/icvts/ivag133
BibTeX
@article{Boltje2026,
author = {Boltje, J W Taco and Velders, Bart J J and Sabik, Joseph F and Oh, Jae K and Ito, Saki and Klautz, Robert J M and Vriesendorp, Michiel D},
title = {Left Ventricular Outflow Tract Diameter Variability and Prosthesis-Patient Mismatch: A Simulation Study},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2026},
volume = {41},
number = {5},
doi = {10.1093/icvts/ivag133}
}
EUVIMED