Aortic Compliance After Root Replacement With Decellularized Homografts Versus in Donor Age-Matched Healthy Controls
Interdisciplinary CardioVascular and Thoracic Surgery · 2026
DOI: 10.1093/icvts/ivaf303 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2026. Verfasst von Tomislav Cvitkovic und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac, Thoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, 30625, Germany. Hauptthemen laut MEDLINE: Aorta, Blood Vessel Prosthesis Implantation, Blood Vessel Prosthesis. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: European Union's HORIZON 2020, European Union’s HORIZON 2020.
Abstract (Originalsprache)
Objectives
We sought to evaluate compliance and flow of the ascending aorta of patients with decellularized aortic homografts compared to donor age-matched healthy controls.
Methods
Male patients and donor age-matched male healthy controls were included. Cardiac function was evaluated by retrospectively electrocardiography-gated cine balanced steady-state free precession magnetic resonance imaging (MRI). Time-resolved 2- and 3-dimensional phase-contrast sequences were used to determine relative area change and pulse wave velocity as surrogate parameters for vessel compliance as well as maximum blood flow velocity.
Results
Thirteen patients were matched according to the age of their homograft donor (median 42 years, interquartile range [IQR] 32-50) to 7 healthy controls (median 40 years, IQR 36-48). Time to post-operative MRI was 3.33 (1.33-4.50) years. Relative area change in the proximal ascending aorta was significantly lower in the homograft group compared to healthy controls (26%, IQR 23-44 vs 38%, IQR 24-44, P < .001), with no significant difference observed in the distal ascending aorta (22%, IQR 22-33 vs 34%, IQR 22-41, P = .438). Maximum blood flow velocity in the proximal ascending aorta was significantly higher in the homograft group compared to healthy controls (168 cm s−1, IQR 148–188 vs 115 cm s−1, IQR 114-120, P = .009).
Conclusions
Decellularized aortic homograft patients seem to have a reduced compliance of the proximal ascending aorta compared to donor age-matched healthy controls. This may be attributable to the in vitro decellularization process or post-operative graft degeneration. These findings highlight the ultimate need for follow-up data to understand the long-term in vivo effects of decellularized human tissue. This study is a follow-up study of the patients included in the ARISE Study registered on ClinicalTrials.gov (NCT02527629). For the purposes of this manuscript, healthy individuals were subsequently recruited to serve as the control group.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac, Thoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, 30625, Germany.
- Department of Pediatric Cardiology and Intensive Care Medicine, Hannover Medical School, Hannover, 30625, Germany.
- Department of Cardiology and Angiology, Hannover Medical School, Hannover, 30625, Germany.
- Department of Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, 30625, Germany.
ORCID-Profile: Tomislav Cvitkovic, Alexander Horke, Philipp Beerbaum, Dietmar Boethig, Samir Sarikouch
Förderung
- European Union's HORIZON 2020
- European Union’s HORIZON 2020
Zitieren
APA
Cvitkovic, T., Horke, A., Bobylev, D., Avsar, M., Holst, T., Beerbaum, P., Boethig, D., Petena, E., Tsimashok, V., Westhoff-Bleck, M., Gutberlet, M., Beyer, F. H., Wacker, F., Ruhparwar, A., Vogel-Claussen, J., Sarikouch, S., & Czerner, C. (2026). Aortic Compliance After Root Replacement With Decellularized Homografts Versus in Donor Age-Matched Healthy Controls. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf303
Vancouver
Cvitkovic T, Horke A, Bobylev D, Avsar M, Holst T, Beerbaum P, et al. Aortic Compliance After Root Replacement With Decellularized Homografts Versus in Donor Age-Matched Healthy Controls. Interdisciplinary CardioVascular and Thoracic Surgery. 2026. doi:10.1093/icvts/ivaf303
BibTeX
@article{Cvitkovic2026,
author = {Cvitkovic, Tomislav and Horke, Alexander and Bobylev, Dmitry and Avsar, Murat and Holst, Theresa and Beerbaum, Philipp and Boethig, Dietmar and Petena, Elena and Tsimashok, Valery and Westhoff-Bleck, Mechthild and Gutberlet, Marcel and Beyer, Frerk Hinnerk and Wacker, Frank and Ruhparwar, Arjang and Vogel-Claussen, Jens and Sarikouch, Samir and Czerner, Christoph},
title = {Aortic Compliance After Root Replacement With Decellularized Homografts Versus in Donor Age-Matched Healthy Controls},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2026},
doi = {10.1093/icvts/ivaf303}
}
EUVIMED