Aneurysm Shape and Sac Shrinkage After Total Arch Replacement With Frozen Elephant Trunk for True Aortic Arch Aneurysm
Interdisciplinary CardioVascular and Thoracic Surgery · 2025
DOI: 10.1093/icvts/ivaf200 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2025. Verfasst von Shinji Abe und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Oji General Hospital, Tomakomai, 053-8506, Japan. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis Implantation, Blood Vessel Prosthesis, Endovascular Procedures. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
This study aimed to evaluate midterm outcomes and identify predictors of sac shrinkage following total arch replacement with a frozen elephant trunk (TAR-FET) for true aortic arch aneurysms.
Methods
A retrospective analysis was conducted on 28 patients who underwent elective TAR-FET for true arch aneurysms between July 2014 and March 2022. Postoperative sac changes on CT were categorized as shrinkage (≥5 mm reduction), enlargement (≥5 mm increase), or no change (<5 mm change). The sphericity index, a novel morphological parameter, was calculated by dividing the average axial and sagittal sac diameters by sac length.
Results
The median age was 74 years, and 23 were male. No operative deaths or recurrent laryngeal nerve palsy occurred. Among 28 patients, 12 experienced sac shrinkage attributable to the initial TAR-FET. Over a median follow-up of 3.6 years, 12 cases showed shrinkage, 2 enlargement, and 14 no change. Cumulative shrinkage rates at 1, 2, and 3 years were 42%, 47%, and 47%, respectively. Additional thoracic endovascular aortic repair (TEVAR) was required in 5 patients (22% at 3 years). Multivariable analysis showed that shorter preoperative sac length (subdistribution hazard ratio [SHR] 0.96; 95% CI, 0.93-0.99) and a higher sphericity index (per 0.1 increment: SHR 1.38; 95% CI, 1.21-1.57) were independently associated with sac shrinkage.
Conclusions
TAR-FET resulted in sac shrinkage in a substantial proportion of patients. Aneurysms that were shorter and more protruding, as indicated by a higher sphericity index, may be more likely to exhibit postoperative sac shrinkage. Clinical Registration Number 022-0242; 16 November 2022 (Ethics Committee of Hokkaido University Hospital).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Oji General Hospital, Tomakomai, 053-8506, Japan.
- Department of Cardiovascular Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo 060-8648, Japan.
ORCID-Profile: Shinji Abe, Yasushige Shingu, Satoru Wakasa
Zitieren
APA
Abe, S., Shingu, Y., Minamida, T., Kato, N., Sugiki, H., & Wakasa, S. (2025). Aneurysm Shape and Sac Shrinkage After Total Arch Replacement With Frozen Elephant Trunk for True Aortic Arch Aneurysm. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf200
Vancouver
Abe S, Shingu Y, Minamida T, Kato N, Sugiki H, Wakasa S. Aneurysm Shape and Sac Shrinkage After Total Arch Replacement With Frozen Elephant Trunk for True Aortic Arch Aneurysm. Interdisciplinary CardioVascular and Thoracic Surgery. 2025. doi:10.1093/icvts/ivaf200
BibTeX
@article{Abe2025,
author = {Abe, Shinji and Shingu, Yasushige and Minamida, Taro and Kato, Nobuyasu and Sugiki, Hiroshi and Wakasa, Satoru},
title = {Aneurysm Shape and Sac Shrinkage After Total Arch Replacement With Frozen Elephant Trunk for True Aortic Arch Aneurysm},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2025},
doi = {10.1093/icvts/ivaf200}
}
EUVIMED