EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC 4.0

Recapture technique for the surgical explantation of an infected self-expanding prosthesis after transcatheter aortic valve replacement prior to surgical aortic valve replacement

Koki Kurosaka, Kenji Iino iD, Yoshitaka Yamamoto, Hirofumi Takemura

Interdisciplinary CardioVascular and Thoracic Surgery · 2025

DOI: 10.1093/icvts/ivaf135 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2025. Verfasst von Koki Kurosaka und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Kanazawa University, Kanazawa, Japan. Hauptthemen laut MEDLINE: Prosthesis-Related Infections, Heart Valve Prosthesis, Device Removal, Transcatheter Aortic Valve Replacement. Die Arbeit nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing use of transcatheter aortic valve replacement (TAVR) has led to a rise in cases of infectious endocarditis (IE), a serious complication. For patients who can tolerate surgery, transcatheter heart valve (THV) explantation is considered, though it carries risks of injury to adherent tissues. This report presents a method to minimize such risks during THV removal. An 82-year-old man with hypertension, smoking history and dyslipidaemia underwent TAVR with a 29-mm Evolut FX bioprosthetic valve. Six months later, he developed a fever, and blood cultures revealed Streptococcus gordonii, leading to an IE diagnosis. Despite 3 months of antibiotics, a transoesophageal echocardiogram revealed vegetation growth and valve leakage, necessitating surgery. During the operation, the aorta was incised, and a novel technique using a vinyl chloride tube was employed to retract and protect the THV’s stent frame. This approach helped detach adhesions with minimal tissue damage. The infected valve was successfully replaced with a bioprosthetic valve. By reducing adherent tissue injury, this technique could improve patient outcomes and decrease the need for additional procedures. Explantation of THVs with minimal tissue damage reduces the risk of concomitant procedure and results in low mortality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis-Related InfectionsHeart Valve ProsthesisDevice RemovalTranscatheter Aortic Valve ReplacementBioprosthesisEndocarditis, BacterialStreptococcal InfectionsAortic Valve StenosisStreptococcus gordoniiAortic ValveHeart Valve Prosthesis ImplantationHumansAged, 80 and overMaleProsthesis DesignTreatment OutcomeEchocardiography, TransesophagealAnti-Bacterial Agents

Stichwörter der Autor:innen

Concomitant surgeryIE after TAVRTAVITHV explantation

Substanzen

Anti-Bacterial Agents

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, Kanazawa University, Kanazawa, Japan.

ORCID-Profile: Kenji Iino

Zitieren

APA

Kurosaka, K., Iino, K., Yamamoto, Y., & Takemura, H. (2025). Recapture technique for the surgical explantation of an infected self-expanding prosthesis after transcatheter aortic valve replacement prior to surgical aortic valve replacement. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf135

Vancouver

Kurosaka K, Iino K, Yamamoto Y, Takemura H. Recapture technique for the surgical explantation of an infected self-expanding prosthesis after transcatheter aortic valve replacement prior to surgical aortic valve replacement. Interdisciplinary CardioVascular and Thoracic Surgery. 2025. doi:10.1093/icvts/ivaf135

BibTeX
@article{Kurosaka2025,
  author = {Kurosaka, Koki and Iino, Kenji and Yamamoto, Yoshitaka and Takemura, Hirofumi},
  title = {Recapture technique for the surgical explantation of an infected self-expanding prosthesis after transcatheter aortic valve replacement prior to surgical aortic valve replacement},
  journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
  year = {2025},
  doi = {10.1093/icvts/ivaf135}
}
Kostenlos starten →